B l u e B o x – B l u e G a t e S e r v e r C o n f i g u r a t i o n
GO Systemelektronik GmbH Faluner Weg 1 24109 Kiel Germany Tel.: +49 431 58080-0
Fax: -58080-11
Page 86 / 96
www.go-sys.de
Appendix D – BlueGate Server Configuration Example
BlueBox settings:
see also
8.2.1.1.5.1 UDP Settings
Menu Internet Settings 8.2.1.1.5
Enter the IP address using the numeric buttons
in the marked block.
see
6 The Configuration Data Sheet
:
3. BlueGate Settings:
IP Address
212.51.30.18
Password BlueGate
xxxxx
Router settings:
For transmission of measurement data to the BlueGate Server the following port must be configured:
•
Port 14112 UDP
212.51.30.18
For bidirectional communication with the BlueBox the following port must be configured:
•
Port 14003 TCP
212.51.30.18
For Windows-Software communication the following port must be configured:
•
Port 14002 TCP
datagateway.go-sys.de
If a time server is connected to the BlueBox the following configuration is necessary:
•
Port 123 UDP (NTP protocol)
Timeserver IP.
Note: If the internal network is not a Class A, B or C network then communication with the BlueBox is only
possible over:
•
Port 14110/TCP (SSL encrypted)
Unencrypted communication with the BlueBox is only possible from the following networks:
•
10.0.0.0/8
Class A network
•
172.16.0.0/12
Class B network
•
192.168.0.0/16
Class C network