GMT 050
User manual
36
Pressurizing the accumulator in case of low pressure
Two persons are required in order to increase the pressure!
Method:
Before pressurizing the accumulator, the regulator valve on the accumulator testing/pressurizing kit
(see below photograph) must be fully closed!
Attach the hose on the regulator valve side to test point J. Attach the hose on the manometer side to
the accumulator test point. Use a (pipe) wrench to tighten the swivel on the test hose!
Once attached, the grapple open function can be operated. As soon as the grapple reaches tilt up
position, the 2
nd
person must slowly open the regulator valve for at least 30 seconds. The accumulator
will now be pressurized.
Excess pressure
Leave the regulator valve on the accumulator filling kit closed. When the grapple is in the default
position, grapple open and tilt down read the manometer value. The final value should be in this
position 580 psi [40 bar] . If the pressure is above the 580 psi [40 bar], it can simply be lowered.
Carefully open the regulator valve next to the manometer and wait until the pressure drops to the
correct level. Close the regulator valve and detach the pressurizing kit.
Accumulator measuring/filling set