TROUBLE-SHOOTING
22
10/12
Fault condition 5
The end sleeve is not separated from band.
Open the cover and disconnect the
mc 25 from mains supply!
If the cutter (1) is damaged or broken off, the cable
crimped with the end sleeve will not be separated
from the band.
In this case remove the tool insert (see also
chapter
retooling
) and check the cutter (1). When
the cutter (1) is defective, the end-sleeve locator
(3) must be removed by unscrewing the cross-
head screw (2) and a new locator for the corre-
sponding cross section must be fitted.
The corresponding article number is stated in
chapter
spare parts.
Fault condition 6
Counter respectively mc 25 do not work.
1. Check mains connection
Check that the mains cable is connected with the appropriate connectors to the mc 25 and the
mains supply. Make sure that you have supply to the plug socket is properly.
2. Check mains fuses
Mains connection must be opened,
disconnect the mc 25 from mains!
Pull out mains plug (1).
Pull out the fuse holder (2).
Check the mains fuses (3).
Replace defective mains fuses. The corre-
sponding article number is stated in chapter
spare parts.
Put the mains fuses into fuse holder.
Insert the fuse holder.
Diagram 28
Check the cutter
Diagram 29
Check mains fuses
!
Fuse holder must click into place.
Summary of Contents for MC 25
Page 2: ...MC25...
Page 3: ...MC25 Betriebsanleitung MC 25 Ausgabedatum 01 2020 F r k nftige Verwendung aufbewahren...
Page 4: ...MC25...
Page 6: ...10 12...
Page 35: ...MC 25 Instruction for use MC 25 Date of issue 01 2020 Save this instruction for further use...
Page 36: ...MC 25...
Page 38: ...10 12...
Page 67: ...Instructions d emploi MC 25 Date d dition 01 2020 A conserver pour utilisation ult rieure...
Page 68: ......
Page 70: ...10 12...
Page 100: ......
Page 102: ...10 18...