Point-to-Multipoint With Repeater
Set the Host, Repeater and Remote GINAs as follows (refer to figure 5-5).
Setting Host Unit
1.
Set TXID = *1 (Transmit ID)
2.
Set TXP = *99 (Transmit path) must equal RID value set in
Repeater
All other parameters are set to default.
Setting Remote Units
1.
Set TXID = *2-98. Remote TXIDs must be different from the host
TXID.
2.
Setting remote TXIDs with all of the same value will not allow
Remotes to communicate with other remotes.
3.
Setting the remote TXIDs to different values will allow remotes to
intercommunicate.
Note: By using matching and different values, various communication paths
can be established. All communication path MUST GO THROUGH THE
REPEATER. Timing considerations for the repeater unit must be resolved
when programming equipment used in the application
Setting Repeater Unit
1.
Set RID = *99
2.
Set ENR = 1
All other parameters at default values
* Example values