MO003-GB 18/05/06
Operative Manual
Rev.0
Page 18 of 34
It is necessary now block the spin of the contact crawling through the
insertion of the screw TSCE M3x15 to the arm.
With the aid of a screwdriver of the maximum diameter of 2mm, find
the hole of the crawling contact moving with small rotating movements
the oscillating arm until the screwdriver penetrates at least in order of
8mm in the hole of the contact.
Now hold absolutely lock the arms and screw the screw TSCE M3x15
until the bottom of the threaded hole.
N.B: if in screwing the screw is felt to force it means that the hole of the
contact has not been cantered from the screw and therefore must re-
centered following the described modality over.
,
If the crawling contact does not come blocked in correct way prejudice the good
operation of the lamp with the risk of extinction of the same one and short circuit
because of the twisting and of the breach of the electrical cables.
In order to remove the detention of the arm, lower the same one and
remove the detention.
Close the hole with the respective one plug in attached plastic.
3.3 Connecting to electrical plant
,
For the duration of the halogen lamp corresponding to the values declared it needs to be
supplied with V
l
tension:
11,5 < V
la
< 12,5 (Volt ac)
Summary of Contents for SATURNO WALL
Page 30: ...MO003 GB 18 05 06 Operative Manual Rev 0 Page 30 of 34 6 2 Explode drawing...
Page 31: ...MO003 GB 18 05 06 Operative Manual Rev 0 Page 31 of 34...
Page 32: ...MO003 GB 18 05 06 Operative Manual Rev 0 Page 32 of 34...
Page 33: ...MO003 GB 18 05 06 Operative Manual Rev 0 Page 33 of 34...
Page 34: ...MO003 GB 18 05 06 Operative Manual Rev 0 Page 34 of 34...