33
Operation
Model: FSH-2, FSH-2A-99
4.03.3
E.A.C. Filter Status & Alarm
[ON]
Indicates that the E.A.C. cell is installed, powered and operating. It is th only light
ON
when the system is
operating normally.
[WASH]
This light turns
ON
to indicate:
• Filter cell is not installed or is mis-aligned.
• Collection fins contain excessive amount of captured grease residue.
• There is poor contact the contact plate inside hood.
• Too many Ionizer wires are missing.
When the
[WASH]
light is
ON
, an alarm condition exists and air cleaner is not
functioning. After approximately two (2) minutes, an intermittent (beeping)
alarm tone begins sounding and shortly thereafter, power to the fryer under the
hood is shutdown; the
[FRYER POWER]
light turns
OFF
.
[WASH}
light is
NOT
intented to be used as a signal for routine cleaning of the
cell,
DO NOT use as such
. Typically, the collection cell must be cleaned
DAILY
to
ensure optimum performance. See
Section 5.01.2, EAC Filter Cell Cleaning
.
[CHECK]
This light turns
ON
to indicate:
• Ionizer wire broken and touching cell frame.
• Cell is damaged and has shorted to ground.
• Collection fins are shorted because of excessive moisture.
When
[CHECK]
light is
ON,
system is no longer functioning to clean the air, even
though the hood continues to run and fryer remains powered.
DO NOT
CONTINUE TO USE FRYER WHEN THIS CONDITION EXIST!
The following actions may clear the alarm condition:
1. Turn
OFF
hood
Power Switch
.
2. Remove the E.A.C. cell and clean as described in
Section 5.01.2
.
3. Inspect the cell for broken or missing ionizer wires, bent fins, or other damage. Ionizer wires are replaceable
(when ordering replacements, note length ... available in
16” or 20”
). Bent fins may be gently straightened by
hand, such that no fin is touching an adjacent fin. A cell with excessive damage (broken frame, badly bent
frame, broken insulators, etc) must be replaced.
4. Inspect the E.A.C. contact plate inside hood. Clean grease accumulation away with a mild degreasing cleaner
and dry thoroughly.
5. Replace filter cell
(
Section 4.02.5
)
and restart Hood
(Section 4.01)
. If the condition persist, contact a qualified
service technician.
If none of the LED lights turn
ON
when hood is started, the power supply may be faulty ... service is required.
Three LED lights on the control panel indicate the operational status of the
Electronic Air Cleaner (E.A.C.)
system.
Summary of Contents for FSH-2
Page 2: ......
Page 4: ......
Page 28: ...18 Installation Model FSH 2 FSH 2A 99 ...
Page 36: ...26 Overview Model FSH 2 FSH 2A 99 ...
Page 45: ...35 Operation Model FSH 2 FSH 2A 99 NOTES ...
Page 46: ...36 Operation Model FSH 2 FSH 2A 99 ...
Page 58: ...48 Parts List Model FSH 2 FSH 2A 99 1 2 3 5 6 8 7 4 Not shown 7 02 Ventless Hood Front ...
Page 64: ...54 Parts List Model FSH 2 FSH 2A 99 Notes ...
Page 65: ......