5
Installation
Model: FSH-2, FSH-2A-99
1. Before unpacking, review dimensions and clearances shown in
Section 1.04.1
or
1.04.2
, and determine
whether the location selected is suitable.
2. Keep the unit and the surrounding area free and clear of combustible materials.
3. Do not obstruct the openings around the exhaust air diverter atop the hood. No minimum clearance (0”) is
required between air diverter and the ceiling, but it is advisable to provide some clearance (>3”) to make
moving the unit easier should the need arise.
4. Provide adequate space for future servicing and proper operation.
5. Hood is equipped with adjustable leveling legs. After final positioning, adjust the legs to level the unit, side
to side, front to back and corner to corner.
6. Before operating, make sure the unit is secured in position and will not move. The front legs of a
FSH-2A-99
Hood
have floor plates for securing the unit to the floor.
This section summarizes procedures necessary for proper equipment installation. To help avoid personal injury or
equipment damage, be sure to adhere to all of these recommended procedures.
Installation is the Purchaser’s responsibility. It is advisable to engage the services of a professional commercial
kitchen equipment specialist, licensed electrician, and qualified HVAC contractor to assist with the details of
installation. Call
Giles Technical Suppor
t @ 800.554.4537, if assistance is required.
2.
Installation
2.01
Location
•
DO NOT ALTER, ADD ATTACHMENTS OR OTHERWISE MODIFY THIS EQUIPMENT.
•
Failure to comply with installation requirements as specified by the Giles Hood Approval Letter will void the
factory warranty.
IMPORTANT!!
Before installing the GILES Recirculating/Ventless Hood system ensure that, A). all necessary approvals from local
code authorities have been obtained, B). the fryer to be used with the hood is within the hood’s listing
limitations, as stated in Section 2.04, and C). the installation site complies with the specific requirements and
limitations outlined in the
GFSE Recirculating/Ventless Hood Approval Letter (HAL)
. The
HAL
is available for
review or download at www.gfse.com under the
SUPPORT
tab in
VENTLESS DOCUMENTS
.
To ensure satisfactory hood performance after installation, the intended site MUST comply with minimum
requirements for kitchen size (>300 sq ft), ceiling height, fresh outdoor air make-up, supplemental exhaust
ventilation, clearances, etc. as stipulated in Giles’ Hood Approval Letter.
•
MAXIMUM of 1 hood per 300 sq ft of commercial kitchen space.
•
Fresh outside air make-up must be equal to a MINIMUM of 15 complete room air exchanges per hour.
•
Giles makes no representations as to the proper design or layout of an establishment in which the ventless
hood will be used. Further, Giles does not perform site inspections prior to installation of any of its units.
• When operating, the hood produces a sound level of approximately
65 dB
.
Summary of Contents for FSH-2
Page 2: ......
Page 4: ......
Page 28: ...18 Installation Model FSH 2 FSH 2A 99 ...
Page 36: ...26 Overview Model FSH 2 FSH 2A 99 ...
Page 45: ...35 Operation Model FSH 2 FSH 2A 99 NOTES ...
Page 46: ...36 Operation Model FSH 2 FSH 2A 99 ...
Page 58: ...48 Parts List Model FSH 2 FSH 2A 99 1 2 3 5 6 8 7 4 Not shown 7 02 Ventless Hood Front ...
Page 64: ...54 Parts List Model FSH 2 FSH 2A 99 Notes ...
Page 65: ......