9
Installation
Model: FSH-2, FSH-2A-99
Model FSH-2:
1. Install appropriate circuit breakers in main electrical panel supplying power for the hood. See
Section 2.03
.
for required circuit breakers. Breaker size given is for the hood only. Appliance requires separate power
supply, see
Figure 2.03.1 (A)
.
2. Remove cover on service entrance box and run appropriate size conduit and wire from box to the electrical
panel supplying hood power. Allow sufficient length of wire and conduit to provide slack needed to properly
access unit for cleaning and service.
3. Make all appropriate connections.
4. Reinstall box cover.
Model FSH-2A-99:
1. Install appropriate circuit breakers in main electrical panel supplying hood power. See
Section 2.03
. for
required circuit breakers.
Breaker size given is for the hood only
.
2. Some
FSH-2A-99
models provide an interlocked power receptacle for the appliance located in the left-side
hood leg or on the rear panel, see
Figure 2.03.1 (B)
.
When installing a hood with the interlocked receptacle,
the breaker size shall be determined by the electrical load of the appliance being placed under the Hood
(max. load is 50A).
2. Remove the upper rear panel to access terminal blocks. Remove one of the large hole plugs and install an
appropriate conduit connector. Route appropriately sized flexible conduit and wire from the electrical panel
supplying hood power. Allow sufficient length of wire and conduit to provide slack needed to access unit for
cleaning and service.
3. Make all appropriate connections as shown in
Figure 2.03.1 (B)
.
4. Reinstall rear panel.
2.03.2 Hood Power Connection
IMPORTANT!
Electrical installation materials (breakers, conduit
&
fittings, wire, etc.) and labor shall be provided by the
customer. Work should be performed by a qualified professional electrical contactor.
Installation must comply with all local code requirements. Giles assumes no responsibility with respect to code
compliance regarding installation and use of this equipment.
Summary of Contents for FSH-2
Page 2: ......
Page 4: ......
Page 28: ...18 Installation Model FSH 2 FSH 2A 99 ...
Page 36: ...26 Overview Model FSH 2 FSH 2A 99 ...
Page 45: ...35 Operation Model FSH 2 FSH 2A 99 NOTES ...
Page 46: ...36 Operation Model FSH 2 FSH 2A 99 ...
Page 58: ...48 Parts List Model FSH 2 FSH 2A 99 1 2 3 5 6 8 7 4 Not shown 7 02 Ventless Hood Front ...
Page 64: ...54 Parts List Model FSH 2 FSH 2A 99 Notes ...
Page 65: ......