![GEZE SecuLogic RWS TZ 300 Installation And Commissioning Instructions With Wiring Diagram Download Page 39](http://html1.mh-extra.com/html/geze/seculogic-rws-tz-300/seculogic-rws-tz-300_installation-and-commissioning-instructions-with-wiring-diagram_2219068039.webp)
SECULOGIC TZ300
39
Appendix
Door control unit TZ300 AP
7.3.2
Technical specifications
Device name
Door control unit TZ300 AP
Versions
TZ 300SN with built-in key switch and PSU
TZ 300S with built-in key switch
Function
Monitoring and controlling an emergency exit door
Dimensions
72 × 197 × 88 (w × h × d)
Installation
Wall mounting
Operating voltage
Versions with PSU: 230 V, 50 Hz
Versions without PSU: 24 V DC (±10 %)
Power consumption
100 mA at 24 V DC (w/o peripherals)
Total power consumption
Versions with PSU: 800 mA
Versions without PSU: Max. 1A (depending on PSU used)
Protection class
Versions with PSU: I according to EN 60950
Versions without PSU: II according to EN 60950
Mounting location
Dry rooms
Ambient temperature
-10 to 50 °C
Directives
German “Guideline on Electrical Locking Systems of Doors
in Escape Routes (EltVTR) – Version December 1997”.
Package content
Mounting plate, preaasembled housing, mounting
accessories, terminals and replacement fuse
Display elements
Catch LED, door LED, alarm LED, buzzer
Buzzer, 75 dB (at about 50 cm distance)
Fuse
F1, 1.5 A, SMF 125 V, fast-acting, 24 V, external
Summary of Contents for SecuLogic RWS TZ 300
Page 41: ...SECULOGIC TZ300 41...
Page 42: ...SECULOGIC TZ300 42...
Page 43: ...SECULOGIC TZ300 43...