SECULOGIC TZ300
17
Operation
Cancelling alarms
5.3
Alarms of the door control unit remain active until their cause has been eliminated and the alarm is acknowl-
edged at the door control unit. (Exception: emergency unlocking through BMA,GMA or RWA, after which the
alarm is automatically reset after 60 seconds; see section 4.4.3.)
Resetting emergency button
5.3.1
When the emergency has passed, the emergency button must be reset.
Remove emergency button cover.
X
Turn emergency button to the right.
X
The emergency button returns to its normal state.
Refit the cover.
X
Acknowledge the alarm.
X
Acknowledge alarm
5.3.2
Precondition:
The alarm cause has been eliminated.
To acknowledge the alarm and lock the door
Turn the key to the right
X
To acknowledge the alarm and unlock the door
Turn the key to the left
X
The door alarm can also be acknowledged through the short-term release input.
A tamper alarm can be acknowledged only 30 seconds after the alarm cause has been eliminated.
For the duration of the tamper alarm the TZ300 remains locked. It can, however, be unlocked with the emergency
button.
If the alarm can not be acknowledged with the key switch, a new alarm may be active. If, for example, the cover
was not refitted after resetting the emergency button, a tamper alarm is triggered when emergency unlocking is
acknowledged, and the door control unit locks the door.
This is indicated by a change in the sound of the audible signal.