![GEZE SecuLogic RWS TZ 300 Installation And Commissioning Instructions With Wiring Diagram Download Page 26](http://html1.mh-extra.com/html/geze/seculogic-rws-tz-300/seculogic-rws-tz-300_installation-and-commissioning-instructions-with-wiring-diagram_2219068026.webp)
SECULOGIC TZ300
26
Wiring diagram
Locking elements
6.5
If the door has several unlocking elements, connect the coils in parallel and the feedback signal cables in series.
Programming
interface
red
(blue)
Holding magnet MA500 (single-leaf doors)
6.5.1
TST300
- X101 (orange terminal strip)
Door contact
L
Locking -
Door locked
24 V DC
Door closed
24 V DC
Holding magnet MA500 (two-leaf doors)
6.5.2
TST300 –
X101 (orange terminal strip)
Door contact
Door contact
L
Locking -
Door locked
24 V DC
Door closed
5)