![GEZE SecuLogic RWS TZ 300 Installation And Commissioning Instructions With Wiring Diagram Download Page 38](http://html1.mh-extra.com/html/geze/seculogic-rws-tz-300/seculogic-rws-tz-300_installation-and-commissioning-instructions-with-wiring-diagram_2219068038.webp)
SECULOGIC TZ300
38
Appendix
Data sheets
7.3
Door control unit TZ300 UP
7.3.1
Technical specifications
Device name
Door control unit TZ300 UP
Function
Monitoring and controlling an emergency exit door
Dimensions
55 × 55 × 37 (w × h × d)
w × h: Button face
d: Distance from support ring upper edge to terminal rear
edge
Installation
UP socket, diameter 60 mm, depth 62.5 mm
Operating voltage
24 V DC (±10 %)
Power consumption
100 mA at 24 V DC (w/o peripherals)
Total power consumption
1 A at 24 V DC (depending on PSU used)
Protection class
II according to EN 60950 (in built-in state)
Mounting location
Dry rooms
Ambient temperature
-10 to 50 °C
Directives
German “Guideline on Electrical Locking Systems of Doors
in Escape Routes (EltVTR) – Version December 1997”.
Package content
Control unit, terminals and replacement fuse
Display elements
Catch LED, door LED, alarm LED, buzzer
Buzzer, 75 dB (at about 50 cm distance)
Fuse
F1, 1.5 A, SMF 125 V, fast-acting, 24 V, external