4.2 I/O Control
The I/O wires connected to the camera provide the interface for one input device and one
output device.
Note:
The I/O settings are only supported by GV-FE2301 / 421 / 4301 / 521.
4.2.1 Input Settings
To activate the sensor input, select
Enable
.
Figure 4-11
Normal State:
You can set the input state to trigger actions by selecting
Open Circuit
(N/O)
or
Grounded Circuit (N/C)
.
Latch Mode:
Enable this option to have a momentary output alarm.
Trigger digital output relay:
When this option is enabled, the output will be triggered
once the input is activated.
Record:
Enable this option to start recording when the input is triggered.
Send Video to Center V2:
Enable this option to send the images to Center V2 when the
input is triggered.
Note:
Triggering the output, recording the images and sending video to Center V2 are
enabled only after you start
Input
monitoring manually or by schedule. To configure the
input monitoring, see
4.4 Monitoring
.