BLIZZARD 400-800 C ENC
19
532104 - Rev.A
2 9
1 2 3 4 5 6
OPEN A OPEN B STOP
- - +
2.5
J6
24 V
"
15 W max
LAMP LAMP
2.5
J9
24 V
"
100mA max
W.L. - W.L. +
2.5
J15
24 V
"
100mA max
OUT - +24V
2.5
J13
3 0
3 1
3 2
3 3
Tr
ansla
tion of the orig
inal instruc
tions
ENGLISH
6.1 CONNECTIONS
L
i
If using a
MASTER-SLAVE
configuration, first read § 10.
Do not exceed the maximum load of the outputs.
TERMINAL BOARD FOR ACCESSORIES
L
i
Multiple
N.O.
contacts on the same input must be connected in paral-
lel. Multiple
N.C.
contacts on the same input must be connected in
series (
).
INPUTS:
1
OPEN A
N.O.
contact: if active, commands the total opening of the gate.
2
OPEN B
N.O.
contact: if active, commands the partial opening of the gate.
Can be configured in Advanced Programming (
Ob
) as:
SAFE
-
N.C.
contact for opening edges.
CLOSE
-
N.O.
contact: if active, commands the closing of the gate.
L
i
If logic
b
or
C
are used, the input
OPEN B
must be
configured as
CLOSE
in Advanced programming
(
Ob
=
02
).
3
STOP
N.C.
stop contact.
Can be configured in Advanced Programming (
SP
) as:
SAFE
-
N.C.
contact for closing edges.
OUTPUTS:
4-5
-
Accessories negative (500 mA max).
6
+
Accessories positive 24 V
"
(500 mA max).
Example of
N.O.
contacts connected in parallel
Example of
N.C.
contacts connected in series
TERMINAL BOARD FOR FLASHING LIGHT (
L
i
The flashing light, if connected to the board, indicates that the auto-
mation is moving.
Terminal board for connecting the flashing light 24 V
"
.
Max load: 15 W.
TERMINAL BOARD FOR OUTPUT W.L. (
)
Output can be configured as a LED or as a timed output in Advanced
Programming (
OL
).
When active, it supplies 24 V
"
.
Max load: 100 mA.
TERMINAL BOARD FOR OUTPUT
OUT
(
Output can be configured in Advanced Programming. The condition
under which it is activated is set in function
O1
.
When active, it supplies 24 V
"
.
Max load: 100 mA.