BLIZZARD 400-800 C ENC
25
532104 - Rev.A
Tr
ansla
tion of the orig
inal instruc
tions
ENGLISH
1 3
Advanced Programming
ADVANCED PROGRAMMING
Default
PF
PRE-FLASHING:
OC
= Sets a pre-flashing of 3 s on the LAMP output, before each
movement.
no
= Pre-flashing on LAMP output disabled.
no
Ph
CLOSING PHOTOCELLS:
Sets the way in which the closing photocells operate
Y
= Stop and reverse during opening when released.
no
= Immediate reverse during opening.
no
OP
OPENING PHOTOCELLS:
Sets the way in which the opening photocells operate
Y
= Immediate reverse during closing
no
= Stop and reverse when released.
no
PO
PARTIAL OPENING:
This sets the partial opening width (
OPEN B
). It can be adjusted
from 00 to 99% of total opening.
50
t
CYCLE TIME-OUT:
Sets the maximum operating time of the gearmotor. Adjustable
from
20
s to
59
s, in steps of 1 s. And from
1.0
to
9.5
min (9 min
and 50 s), in steps of 10 s. Set a longer time for a complete opening
and closing cycle.
EG:
2.5
=2 min. and 50 sec.
9.5
Sr
DECELERATION SPEED
Lo
= standard deceleration speed.
Hi
= high deceleration speed.
Lo
IP
REVERSE ON OBSTACLE MODE:
Y
= Sets partial reverse after an obstacle has been detected by the
encoder
or the safety edge.
no
= Sets total reverse after an obstacle has been detected by
the
encoder
or safety edge.
no
OL
OUTPUT W.L.:
00
= LED, active during opening, when open and open in pause;
flashing during closing; off when gate closed.
01
= Courtesy light, active for the opening movement and for a
further 90 s.
00
O1
OUTPUT
OUT
00
= Always active
01
=
Fail-Safe
test on
SAFE
input
05
= Gate open or open in pause
06
= Gate closed
07
= Gate moving
09
= Gate opening
10
= Gate closing
12
= Safety device active
13
= Traffic light control: output active when the gate is open and
open in pause; output disabled during pre-flashing, when moving
and when the gate is closed
14
= Timed output that can be activated by the second radio
channel (see the next function
tl
)
15
= Step by step controlled by the second radio channel
19
= Battery operation
00
tl
TIMING OF OUTPUT
OUT
:
Sets the activation time of the output
OUT
in timed mode that can
be activated by the second radio channel (
14
). Adjustable from
01
min. to
99
min. in 1 second steps.
02
ADVANCED PROGRAMMING
Default
Ob
INPUT
OPEN B
OPERATION
00
=
OPEN B
- partial opening command.
01
=
SAFE
- contact for opening edges.
02
=
CLOSE
- close command.
00
SP
INPUT
STOP
OPERATION
00
=
STOP
- automation stop command.
01
=
SAFE
- contact for closing edges.
00
St
AUTOMATION SYSTEM STATUS:
Y
to save and exit from programming mode
no
to exit from programming mode without saving
Press button
F
to confirm; when finished, the display reverts to
the automation status display:
00
= Closed
01
= Open
02
= Stationary then opens
03
= Stationary then closes
04
= Paused
05
= Opening
06
= Closing
09
= Pre-flashing then opens
10
= Pre-flashing then closes
14
= Obstacle during opening
15
= Obstacle during closing
Y
Summary of Contents for BLIZZARD 400 C ENC
Page 1: ...BLIZZARD 400 C ENC BLIZZARD 800 C ENC...
Page 33: ......