Part No. 62401
Genie S-100 • S-105 • S-120 • S-125
7 - 61
Section 7 • Repair Procedures
First Edition • First Printing
Control Relay Schematic
3 Connect the leads from an ohmmeter or
continuity tester to each terminal combination
and check for continuity. Terminals 85 and 86
represent the coil and should not be tested in
any other combination.
Test
Desired result
terminal 85 to 86
85 to 95
terminal 87 to 87a & 30
no continuity
(infinite
)
terminal 87a to 30
continuity
(zero
)
4 Connect 12V DC to terminal 85 and a ground
wire to terminal 86, then test the following
terminal combinations.
Test
Desired result
terminal 87 to 87a
no continuity
(infinite
)
terminal 87a to 30
no continuity
(infinite
)
terminal 87 to 30
continuity
(zero
)