CHECKLIST
B
PROCEDURES
B-5
Test the Alarm Package
(if equipped)
Alarms and a beacon are installed to alert operators
and ground personnel of machine proximity and
motion. The alarm package is installed on the
turntable covers.
The alarms and beacon will
operate with the engine
running or not running.
1 Turn the key switch to ground control and pull
out the Emergency Stop button to the on
position at both the ground and platform
controls.
Result: The flashing beacon should be on and
flashing.
2 Push and hold a function enable/speed select
button and the boom down button. Hold for a
moment and then release them.
Result: The descent alarm should sound when
the boom down button is pressed.
3 Turn the key switch to platform control.
Result: The flashing beacon should be on
and flashing.
4 Press down the foot switch. Move the boom
control handle to the down position, hold for a
moment and then release it.
Result: The descent alarm should sound when
the control handle is held down.
5 Press down the foot switch. Move the drive
control handle off center, hold for a moment and
then release it. Move the drive control handle off
center in the opposite direction, hold for a
moment and then release it.
Result: The travel alarm should sound when the
drive control handle is moved off center in either
direction.
2 Release the latches on the air cleaner cap.
Remove the end cap from the air cleaner
canister.
3 Remove the filter element.
4 Clean the inside of the canister and the end cap
with a damp cloth.
5 Inspect the air filter element. If needed, blow
from the inside out using low pressure dry
compressed air, or carefully tap out dust.
Replace the filter if needed.
6 Install the filter element.
7 Install the air filter canister end cap and secure
the end cap latches.