Part No. 62401
Genie S-100 • S-105 • S-120 • S-125
7 - 10
Section 7 • Repair Procedures
First Edition • First Printing
PLATFORM CONTROLS
Turntable rotate functions:
If the calibration fault is already
displayed at the ground box begin
with step 6.
1 Turn the key switch to the off position.
2 Press and hold the enter button
on the
ground control panel while turning the key
switch to platform controls. Hold the enter
button for approximately 5 seconds.
3 Press the minus button
twice, then press the
enter button
twice.
4 Use the scroll button
to scroll through the
menu until
RESET
TURNTABLE
ROTATE
JOYSTICK
DEFAULTS
is displayed. Press the
button to
select
YES
, then press the
button.
5 Exit programming mode.
To exit programming mode, use
the scroll button
to scroll
through the menu until the
screen displays exit, then press
the plus button
once, change
the NO to YES, and press the
enter button
.
6 Do not start the engine.
7 Locate the boom/turntable rotate joystick.
8 Move the boom/turntable joystick full stroke in
the left direction and hold for 5 seconds, then
return to the center or neutral position.
9 Move the boom/turntable joystick full stroke in
the right direction and hold for 5 seconds, then
return to the center or neutral position.
Result: The alarm at the ground controls should
sound for a successful calibration.
Result: If the alarm does not sound, repeat the
calibration procedure, beginning with step 1.
How to Reset a Proportional
Valve Coil Default
Software version 2.0 requires the
use of Web GPI to perform this
procedure. Refer to 5-5
, Software.
This procedure only needs to be
performed if a proportional valve
has been replaced.
After the valve coil defaults have
been set, each machine function
threshold and default function
speed must be set. See
How to
Set the Function Thresholds and
Default Function Speeds.
1 Turn the key switch to the off position.
2 Press and hold the enter button
on the
ground control panel while turning the key
switch to platform controls. Hold the enter
button for approximately 5 seconds.
3 Press the minus button
twice, then press the
enter button
twice.
4 Use the scroll button
to scroll through the
menu until the function valve that needs to be
reset is displayed. Press the
button to
select
YES
, then press the
button to save the
setting.
Choices are: Propel (drive) valve
reset; Boom up/down valve reset;
Boom extend/retract valve reset;
or TT rotate valve reset.
5 Push one of the LCD screen buttons shown
until
EXIT
is displayed.
6 Press the plus
button or minus button
to
select
YES
and then press the enter button
.
REV B
Summary of Contents for S-100