Part No. 62401
Genie S-100 • S-105 • S-120 • S-125
7 - 118
Section 7 • Repair Procedures
First Edition • First Printing
3 Tag, disconnect and plug the hydraulic hoses
from the manifold that is mounted to the motor.
Bodily injury hazard. Spraying
hydraulic oil can penetrate and
burn skin. Loosen hydraulic
connections very slowly to allow
the oil pressure to dissipate
gradually. Do not allow oil to squirt
or spray.
4 Remove the motor/brake mounting fasteners.
Remove the motor from the brake.
a
motor
b
motor/brake mounting bolts
c
brake
d
drive hub mounting bolts
e
drive hub
12-1
Turntable Rotation Hydraulic
Motor and Drive Hub
How to Remove the Turntable
Rotation Hydraulic Motor
When removing a hose assembly
or fitting, the O-ring on the fitting
and/or hose end must be replaced
and then torqued to specification
during installation. Refer to
Section Two,
Hydraulic Hose and
Fitting Torque Specifications.
1 Secure the turntable from rotating with the
turntable rotation lock pin.
2 Remove the ground controls side fixed turntable
cover. See 5-1,
How to Remove a Fixed
Turntable Cover.
Turntable Rotation Components
unlocked
locked
b
a
c
d
e
Summary of Contents for S-100
Page 1: ......