Pelco
genetec.com | Omnicast Video Unit Configuration Guide 4.8 SR3
71
EN.100.007-V4.8.C3.(1)
Pelco
This section describes the additional configuration steps required for some Pelco units to work
in Omnicast.
This section includes the following topics:
•
"Configuring motion detection"
•
"Adding NET54xx encoder series"
•
"Configuring dual-streaming for Pelco IP series"
•
•
"Configuring Pelco Sarix units"
•
"Naming Sarix Spectra HD PTZ preset tours"
•
"Configuring the CM9760-CC1 for use with the Pelco DMR protocol"
Configuring motion detection
Best practice:
When using H.264 motion detection with Pelco units, it is recommended that
you disable all automatic image adjustments on the unit’s Web page.
Adding NET54xx encoder series
The NET54xx encoder series can have a range of one to four channels. Each channel must have
a different IP address. Therefore, units like the NET5402T which have two channels, must be
added twice in Omnicast, once for each IP address.
Configuring dual-streaming for Pelco IP series
When using dual-streaming with Pelco IP series units, the video stream settings for each stream
are linked. For example, the video settings you define for the primary stream tab (MPEG-4-1)
are automatically applied in the secondary stream tab (MPEG-4-2).
Configuring NET5301T units
No serial port entity is created for Pelco NET5301T units in Omnicast. Therefore, to configure
the serial port and enable PTZ, you must use the
Specific Settings
tab in the Config Tool.