
Mavix
genetec.com | Omnicast Video Unit Configuration Guide 4.8 SR3
62
EN.100.007-V4.8.C3.(1)
Configure MediaRacer 250 units
Mavix MediaRacer 250 units have a unique video input that provides two streams which can be
configured independently using the Mavix Configurator.
•
"Select H.264 or MPEG-4 streaming"
•
"Configure the stream settings"
Select H.264 or MPEG-4 streaming
1
Open the Mavix Configurator and enter
Administrator
as the default username and
Admin
as the password.
2
Select the
Update Firmware
icon.
3
Under
Connect to
in the
Manual Update
tab, type the unit IP address.
4
Type the username and password of the unit.
5
Under
MediaRacer
, select
250
.
6
From the drop-down list in the dialog box, select
taskman.ini
.