GM9907-L5
bulk scale controller user’s manual
- 61 -
Process description as follow
:
Process Description
:
Start
Coarse feed
Set Target none 0,input start signal,judge supplement Empty
signal,if signal OFF,wait till ON.
Filling PreDelay Timer Dela
y
COMP.
Inhibit
Timer(Co-F)
coarse feed start,to avoid overshoot,
“
coarse feed Inhibit Timer
”
doesn’t judge weight.After time finish,controller monitors
weight in real time.weight
≥
Target
-
Co-Feeding
Remains
,
enter fine feed process.
Fine feed
COMP. Inhibit Timer(Fi-F)
fine feed start ,to avoid overshoot,
“
fine feed Inhibit Timer
”
doesn’t judge weight. After time finish,controller monitors
weight in real time. weight
≥
Target-Free fall
,
enter WAIT
process
WAIT
“
Result Waiting Timer
”
finish,controller output
OVER/UNDER
(
OVER UNDER detect ON
)
or output discharge
Fill-Go
If I/O Function input defined
“
Fill-Go
”
, need to input Fill-Go
ON
,
wait Feedling Start Delay finish,start filling;if not
define“Fill-Go”,no need to wait Fill-Go start filling.
Result Waiting Timer