GM9907-L5
bulk scale controller user’s manual
- 13 -
quantitative process or input emergency stop signal to clear
the alarm and return to the stop state.
Over/Under
Alarm
Timer
Over/Under test is turn to ON, after “Result Waiting Timer”
finish,when hopper is stable, starts Over/Under test and output
Over/UnderAlarm Timer
,
when time up enter discharge.
Initial value
:
2.0
range
:
0.0~99.9
(
Unit:
s
)
OVER
Limit Value
In the quantification process, if the weighing value
≥
Over Limitation
,
it is judged as Over.
Initial value
:
0.0
,
range
:
0~Capacity
Under Limit
Value
In the quantification process, if the weighing value
≤
Target-Under Limitation,it is judged as Under.
Initial value
:
0.0
,
range
:
0~Capacity
Flowrate
Function
Used to set flowrate function to adjust relevant parameters
Target
Flowrate
ON/OFF
“On / Off” is optional. Initial value
:
OFF. (Note
:
when is on,
have below parameters
)
Target
Flowrate
value
Target flowrate function is ON, set ”Target Flowrate value”,
when controller is running, according to setting the target
flowrate value and target value to calculate and
transform,calculate the time required to carry out a filling
process,then the controller waits for the calculated time before
starting discharge.
Initial value
:
0.00t/h
,range
:
0.00~9999.99
Flowrate
Low Alarm
When it is opened, the number of times when the actual
discharge interval time continuously exceeds the calculated
discharge interval time exceeds the number of “Flowrate Low
Alarm Trigger Count", the alarm will be reported. Closed, no
alarm.
“On / Off” is optional
,
Initial value
:
OFF
Flowrate
Low Alarm
Trigger
Count
After the switch of insufficient flow alarm function is opened,
the discharging interval time is timed out for several
consecutive times, and the number of times reaches the value
set, the controller outputs "insufficient flow" alarm signal. Set
to 0, no alarm.
Initial value
:
0
,
range
:
0~99
(
Unit
:
pcs
)
Flowrate
Low Auto
Adjust
ON/OFF
Automatic adjustment function switch after insufficient flow
(discharging interval timeout) .When the switch is opened, if
the discharging interval has a timeout, the controller will
automatically adjust and shorten the discharging interval time
of each scale until the timeout time is offset. “On / Off” is
optional
,
Initial value
:
OFF
Motor
Used to set parameters related to the filling motor group ID used in the