GM9907-L5
bulk scale controller user’s manual
- 47 -
I18
Start/Stop(LS)
When the signal is valid, the controller executes start;
when the signal is invalid, the controller executes stop to
stop feeding and enters state directly. When discharge is
completed, Alarm " Delivery done".
I19
Manual DISC
Used to manually clear the material in the metering
hopper. This input is valid once discharge output is valid
again discharge output is invalid. The input is respond
only under stop state.
I20
Manual DISC
(
LS
)
The signal is valid, discharge output is valid; Discharge
Outputs invalid. The input is respond only under stop
state.
I21
Manual Fi-Fill
This input is valid once controllerFine feed output is
valid; Again, the ControllerFine Feed outputs invalid
I22
Manual Fi-Fill
(
LS
)
The ControllerFine feed output is valid when the signal
is valid, and invalid when the signal is invalid.
Respond the signal only under stop state.
I23
Manual Co-Fill
When set to combined feeding mode: the coarse feed
and Fine feed output are valid once, and the coarse feed
and Fine feed output invalid again.
Set to single feeding mode: The coarse feed output is
valid once output is invalid again. The input is respond
only under stop state.
I24
Manual Co-Fill
(
LS
)
When signal is valid, controller coarse,fine feed output
is valid, when signal is invalid, controller coarse, fine
feed output is invalid.
The input is respond only under stop state.
I25
Filler Gate Closed
Pos.
motor drive feeding mode is valid, connect feeding gate
close to signal input
I26
DISC Gate Opened
Pos.
Connect discharge gate open to signal input
I27
DISC Gate Closed
Pos.
When feeding if discharge gate close to signal invalid
then close feeding signal output. (stop state manual
discharge do not judge discharge gate closed)
4.5.2 IO
test
User can use IO test to check whether the controller output and input interfaces are
properly connected to external devices. Before running IO test, turn test ONOFF ON and