GM9907-L5
bulk scale controller user’s manual
- 46 -
to be valid in the state before feeding. The signal is not
judged during feeding. Eg If the signal is not defined,
the controller does not judge before feeding.
I7
Clogged(In)
The signal effectively represents that the discharge
mechanism of the lower-level device is blocked. After
the value is set, the controller will not discharge signal.
The controller can discharge signal only after the signal
becomes None.
I8
Change Recipe
This input is valid once, and the Recipe ID changes to
the next Recipe whose Target is not zero, skipping the
Recipe ID whose Target is zero. Returns 1 if the Recipe
ID is greater than 20. After Change Recipe, restart
Recipe ID to save after power failure.
I9
Print Total ACUM
In stop state, the entered valid controller can print
ACUM (Protocol must be set to Print).
I10
Supplement Full
Used to connect the Supplement Full of the hopper, the
input shall be the level input.
I11
Supplement OK
Used to connect the Supplement ok of the hopper, the
input shall be the level input.
I12
Supplement
NotEmpty
Used to connect the Supplement empty of the hopper,
the input shall be the level input. When valid is
Supplement Full, invalid isSupplement Empty.
I13
Clear Total ACUM
Once this input is valid, the controller clears all ACUM
data values, including recipe ACUM weight, user
ACUM weight, and in&out ACUM. Respond the signal
only under stop state.
I14
Clear In&Out ACUM
In stop state, the Controller clears in&out ACUM weight
Data when the signal changes from invalid to valid.
I15
Clear Present Recipe
ACUM
The ACUM data value of the controller's current recipe
after this input is valid.
Respond the signal only under stop state.
I16
Clear Present User
ACUM
After this input is valid, the controller ACUM data value
of the current user.
Respond the signal only under stop state.
I17
Start/E-Stop(LS)
Level Signal.The controller starts when the signal is
valid, and stops when the signal is invalid.