GM9907-L5
bulk scale controller user’s manual
- 18 -
Port No.
Initial value
:
502; 0~65535
IP address
Initial value
:
192.168.101.246; 0~255
MAC address
BC.66.41.9X.XX.XX
Auto Print
ON/OFF
,
Initial value
:
OFF. When choose
“
ON
”
When the packaging is completed, the packaging
result will be automatically printed (serial port is
required and select "Print").
Printer Format
Initial value
:
32
Columns
;
24
Columns
/
32
Columns
Printing
Language
Initial value
:
English
;
Chinese
/
English
Print Empty
Line Nos.
Print Line Nos.
,
Initial value
:
3
;
0~9
4.4.1
S
Continuous Send
Mode
When self-send Mode is set to COM para. serial port 1 or serial port 2, there is no need
to send any command to the controller in this Mode, and the controller automatically sends
the collected data to the supreme bit machine. Its data frame format is as follows
STX
COM
ID
C
S
state1 state2 state3
+/-
display
value
CRC
CR
LF
02H
Not
e1
43H 53H Note2 Note2 Note2
Not
e2
Note2
Note1
0DH
0AH
Note1
:
COM ID
— —
2
bit, when COM ID is
01
,
30H 31H
CRC
— —
The checksum, in which all the preceding values are added and converted to
decimal, and then the last two bits are taken and converted to ASCII. (ten
bits first and one last), two bits
Note2
:
state
1
——
30H
:
stop or un stop state
,
31H
:
before feed
,
32H
:
coarse feed
,
33H
:
fine
feed
,
34H
:
Result Holding
(
feed finish
),
35H
:
discharge
,
36H
:
send and
receive finish
state
2
——
M
:unstable
4DH
,
S
:stable
53H
,
O
:OFL
4FH
state
3:
— —
G:
Gross State 4
7H
,
N
:
Net Weight
4EH
+/-
—— signal
,
+
:
2BH
,
-
:
2D
H
display value ——
7
bit, include decimal point, high bit
0 is empty
.