GM9907-L5
bulk scale controller user’s manual
- 45 -
O15
Remote Ctr Output1
The output state of the I/O Function can be controlled
by serial port communication protocol Modbus.
O16
Remote Ctr Output2
The output state of the I/O Function can be controlled
by serial port communication protocol Modbus.
O17
Remote Ctr Output3
The output state of the I/O Function can be controlled
by serial port communication protocol Modbus.
O18
Remote Ctr Output4
The output state of the I/O Function can be controlled
by serial port communication protocol Modbus.
O19
Remote Ctr Output5
The output state of the I/O Function can be controlled
by serial port communication protocol Modbus.
O20
Cut Material
The output is valid during feeding period and invalid
during non-feeding period
O21
Filler Open(Motor)
Control motor open feed gate
O22
Filler Close(Motor)
Control motor close feed gate
O23
DISC Gate
Open(Motor)
Control motor open DISC gate
O24
DISC Gate
Close(Motor)
Control motor close DISC gate
Input value
I0
None
this input is Input value
I1
Start
The signal valid controller will enter the running
state.This input is a pulse input signal.
I2
E-stop
The signal valid controller will return to the stop
state. This input is a pulse input signal.
I3
Stop
The signal valid controller will return to the stop state
after completing the current bagging process. This input
is a pulse input signal.
I4
ZERO
The signal valid controller will clear the weight. This
input is a pulse input signal.
I5
Clear Alarm
Used to clear the alarm output of the controller. This
input is a pulse input signal.
I6
Fill Permission
Level signal, eg if the signal input is defined, the
controller will enter the feeding state only when the
controller determines that the signal is valid before
feeding; otherwise, the controller will wait for the signal