SC-ADT Configuration
Configuring SC-ADT for Typical Applications
3-8
SpectraComm ADT
076R172-000
Installation and Operation Manual
Issue 2
3. To enable the Telnet menu, type:
configure ports tel-menu enable
4. For Transport mode only, configure each port for transport mode and with its remote port
number and IP address by typing:
configure ports tport port
[n] [remote IP address] [remote port number]
For example:
configure ports tport port5 192.200.12.6 port16
Note
For Transport applications, mode and IP address commands are automatically sent to the remote device.
5. Enable each configured Terminal Server or Transport port by typing:
configure ports enable port
[#] or
all
For example:
configure ports enable all
Note
For Transport applications, the
ports enable
command is automatically sent to the remote device.
6. Configure the communication rate for each Terminal Server port for compatibility with the
attached device. The default value is 9600.
configure ports comms port
[#]
For example:
configure ports comms port1 19200
7. Configure the flow control for any port as XON, XOFF, Hardware, or None, by typing:
configure ports flow-control port
[6] or
all
For example:
configure ports flow-control port6 None
8. You can check your port configurations individually by typing the following command:
show ports info port
[n]