V 10/17
28
•
Maintenance
MagicCompact BA04
Maintenance and repair of the cyclone separator
The following activities on the cyclone should be carried out regularly:
–
Remove powder deposits and caked powder
–
Check the gaskets, sealing strips and locking mechanisms (covers
etc.) for functioning and sealing
–
Replace the material abraded from the cyclone inside walls by abra-
sive powders (by build-up welding)
Further information, see the corresponding operating manual!
Maintenance and repair of the sieve machine
The following activities on the sieve machine should be carried out regu-
larly:
–
Check the gaskets and if necessary, replace them
–
Clean the sieve mesh, or if damaged, replace it
Further information, see the corresponding operating manual!
Maintenance of the After Filter pressure gauges (filter
and fan)
The following check should be carried out regularly:
–
Notice the pressure on the pressure gauges and compare with the
original pressure values, which were set by the Gema service engi-
neer at the first start-up
–
If errors arise, see the troubleshooting guide and the After Filter op-
erating instructions
–
If it is not possible to adjust the original settings, please contact an
Gema service center
Further information, see the corresponding operating manual!
Replacing spare parts
Spare parts are to be replaced by trained personnel only. The plant must
always be switched off, when replacing spare parts. Spare parts can be
ordered from the spare parts list.
NOTE:
Only original Gema spare parts should be used!