V 10/17
MagicCompact BA04
Operation
•
25
– Open the cyclone cone and remove the sieve, leave the cyclone
open
– Remove the recovery hose from the powder container
6.
Clean the booth
– if necessary, move the guns out of the booth
– if necessary, clean the muzzles etc.
– Blow off the booth with the air lance, clean the suction opening
– if necessary, wipe off the booth walls
7.
Clean the OptiCenter
– if necessary, change the powder hoses (bright/dark)
– Clean the OptiCenter
8.
Clean the recovery system
– Connect the recovery hose to the blow off connector
– Open the cyclone cone and clean the sieve
– Blow off the recovery system
– if necessary, wipe off the cyclone cone
– Blow off the inside of the monocyclone with the air lance
9.
Prepare the equipment for coating
– Make the recovery system ready for operation
– Put the OptiCenter into coating operation
– Put the booth into coating operation (switch on the plant, move
the XT axis into coating position, start the correct reciprocators
program)
10. Check the guns for functioning (high voltage and powder output)
REMARK:
These short instructions should facilitate, above all, the handling of the
plant for the daily, always recurring works. They do not replace by any
means the enclosed manuals of the components, and presuppose that
you read and understand the corresponding chapters in the operating
manual as well as the safety regulations.