78
AFE200 • Instruction Manual
Menu
PAR
Description
UM
Type
FB BIT
Def
Min
Max
Acc
1.7
282
React curr ref mon
A FLOAT 16/32 0.0
0.0
0.0
ER
The reactive current reference is displayed.
Menu
PAR
Description
UM
Type
FB BIT
Def
Min
Max
Acc
1.8
284
Active current
A FLOAT 16/32 0.0
0.0
0.0
ER
The active current value currently in use is displayed.
Menu
PAR
Description
UM
Type
FB BIT
Def
Min
Max
Acc
1.9
286
Reactive current
A FLOAT 16/32 0.0
0.0
0.0
ER
The reactive current value currently in use is displayed.
Menu
PAR
Description
UM
Type
FB BIT
Def
Min
Max
Acc
1.10
256
Phase U voltage
V
FLOAT 16/32 0.0
0.0
0.0
R
The phase U voltage is displayed.
Menu
PAR
Description
UM
Type
FB BIT
Def
Min
Max
Acc
1.11
258
Phase V voltage
V
FLOAT 16/32 0.0
0.0
0.0
R
The phase V voltage is displayed.
Menu
PAR
Description
UM
Type
FB BIT
Def
Min
Max
Acc
1.12
260
Phase W voltage
V
FLOAT 16/32 0.0
0.0
0.0
R
The phase W voltage is displayed.
Menu
PAR
Description
UM
Type
FB BIT
Def
Min
Max
Acc
1.13
248
Power factor
FLOAT
0.0
0.0
0.0
ER
The power factor value (cosφ) is displayed.
Menu
PAR
Description
UM
Type
FB BIT
Def
Min
Max
Acc
1.14
262
Output power
kW FLOAT 16/32 0.0
0.0
0.0
ER
The value of the power generated into the mains is displayed.
Menu
PAR
Description
UM
Type
FB BIT
Def
Min
Max
Acc
1.15
264
Output energy
kWh FLOAT
0.0
0.0
0.0
ER
The value of the energy generated onto the mains is displayed.
Menu
PAR
Description
UM
Type
FB BIT
Def
Min
Max
Acc
1.16
368
Drive overload accum
perc UINT16 16/32 0
0
100
ER
The AFE overload level is displayed. An instantaneous overload of 180% of the AFE
rated current is allowed for 0.5s. The thermal image I²t adjusts the AFE output current
thresholds. During normal operation, the instantaneous output current value can reach
180% of the AFE rated current. After 0.5s at 180%, the output current threshold is
reduced to 150%. When the overload level
PAR 368 Drive overload accum
reaches
100%, the output current threshold is reduced to 100% of the rated current, and stays
at that value until the I²t integrator cycle is complete. At this point the 180% instantane-
ous overload is re-enabled.
Summary of Contents for AFE200 4 Series
Page 94: ...94 AFE200 Instruction Manual 7 DIGITAL INPUTS ...
Page 97: ... AFE200 Instruction Manual 97 8 DIGITAL OUTPUTS ...
Page 203: ... AFE200 Instruction Manual 203 Commands ...
Page 204: ...204 AFE200 Instruction Manual Digital inputs ...
Page 205: ... AFE200 Instruction Manual 205 Digital outputs ...
Page 206: ...206 AFE200 Instruction Manual Analog inputs ...
Page 207: ... AFE200 Instruction Manual 207 ...
Page 208: ...208 AFE200 Instruction Manual Analog outputs ...
Page 209: ... AFE200 Instruction Manual 209 Current Control ...
Page 210: ...210 AFE200 Instruction Manual Active Curr Config ...
Page 211: ... AFE200 Instruction Manual 211 Functions ...
Page 212: ......
Page 213: ......