62
AFE200 • Instruction Manual
of the parameter (PAR).
When the parameter reached by the “Goto” command is displayed, it is possible
to navigate all the parameters forming part of the same group using the ▲ and ▼
keys.
Pressing the ► key returns to the “Goto” function.
To exit the “Goto” function, press the ► key.
6.3 Parameter modification
To enter parameter modification mode, press the
E
key when the parameter to be
modified is displayed.
To save the value of the parameter, following modification, press the
E
key again.
Note !
To save permanently, see
paragraph 6.4
.
To exit from modification mode without saving the value, press the
ESC
key.
The operations to be carried out to modify the value depend on the type of the
parameter, as described below.
Note !
For further information about the type of parameters displayed, see
.
●
Numeric parameters
T+
T-
EN
LOC
ILim
n:0
AL
01 MONITOR
02 DRIVE INFO
03 STARTUP WIZARD
04 DRIVE CONFIG
E
T+
T-
EN
LOC
ILim
n:0
AL
0 4 . 0 3
PA R :
1 2 0
Input inductance
0.7150
mH
Def: 0.715
T+
T-
EN
LOC
ILim
n:0
AL
0 4 . 0 3
PA R :
1 2 0
Input inductance
Def: 0.715
0 0 0 0 0 . 7 1 5 0
X 3
mH
When
E
is pressed to access modification mode, the cursor is activated on the
digit corresponding to the unit.
Using the ◄ and ► keys, the cursor can be moved to all the digits, including trail
-
ing zeros that are normally not displayed.
With the ▲ and ▼ keys, the digit under the cursor is increased or decreased.
Press
E
to confirm the modification or
ESC
to cancel.
●
Binary parameters (BIT type)
The parameter may assume only two states which are indicated as OFF-ON or
0-1.
X 5
T+
T-
EN
LOC
ILim
n:0
AL
05 REFERENCE
06 COMMANDS
07 DIGITAL INPUTS
08 DIGITAL OUTPUTS
E
T+
T-
EN
LOC
ILim
n:0
AL
0 8 . 0 5
PA R :
1 3 3 0
Dig out 1 inversion
ON
T+
T-
EN
LOC
ILim
n:0
AL
0 8 . 0 5
PA R :
1 3 3 0
Dig out 1 inversion
OFF
Pressing
E
, modification mode is activated. The entire line is displayed in reverse.
Use the ▲ and ▼ keys to move from one state to another.
Press
E
to confirm the modification or
ESC
to cancel.
●
LINK type parameter
The parameter may assume the number of another parameter as value.
Summary of Contents for AFE200 4 Series
Page 94: ...94 AFE200 Instruction Manual 7 DIGITAL INPUTS ...
Page 97: ... AFE200 Instruction Manual 97 8 DIGITAL OUTPUTS ...
Page 203: ... AFE200 Instruction Manual 203 Commands ...
Page 204: ...204 AFE200 Instruction Manual Digital inputs ...
Page 205: ... AFE200 Instruction Manual 205 Digital outputs ...
Page 206: ...206 AFE200 Instruction Manual Analog inputs ...
Page 207: ... AFE200 Instruction Manual 207 ...
Page 208: ...208 AFE200 Instruction Manual Analog outputs ...
Page 209: ... AFE200 Instruction Manual 209 Current Control ...
Page 210: ...210 AFE200 Instruction Manual Active Curr Config ...
Page 211: ... AFE200 Instruction Manual 211 Functions ...
Page 212: ......
Page 213: ......