AFE200 • Instruction Manual
123
2
Ingr1!=Ingr2
3
Ingr1<Ingr2
4
Inrg1>Ingr2
5
|Ing1|=|Ing2|
6
|Ing1|!=|Ing2|
7
|Ing1|<|Ing2|
8
|Ing1|>|Ing2|
If set to
0
the comparator is not enabled
If set to
1
the comparator output is enabled when the value of
Dig compare input 1
is
inside the window resulting from the value of
Dig compare input 2
± the tolerance set
via the
Comparator Window
.
If set to
2
the comparator output is enabled when the value of
Dig compare input 1
is
not inside the window resulting from the value of
Dig compare input 2
± the tolerance
set via the
Comparator Window
.
If set to
3
the comparator output is enabled when
Compare input 1
is less than
Com-
pare input 2
.
If set to
4
the comparator output is enabled when
Compare input 1
is greater than
Compare input 2
.
If set to
5
the comparator output is enabled when the value of
Dig compare input 1
is inside the window resulting from the absolute value of
Dig compare input 2
± the
tolerance set via the
Comparator Window
.
If set to
6
the comparator output is enabled when the absolute value of
Dig compare
input 1
is not inside the window resulting from the absolute value of
Dig compare
input 2
± the tolerance set via the
Comparator Window
.
If set to
7
the comparator output is enabled when the absolute value of
Dig compare
input 1
is less than the absolute value of
Dig compare input 2
.
If set to
8
the comparator output is enabled when the absolute value of
Dig compare
input 1
is more than the absolute value of
Dig compare input 2
.
Menu
PAR
Description
UM
Type
FB BIT
Def
Min
Max
Acc
13.3.6
3672 Compare window
perc
FLOAT
0.0
0.0
100.0 ERW
Setting of the tolerance window for comparing the
Dig compare input 1
and
Dig
compare input 2
signals.
Menu
PAR
Description
UM
Type
FB BIT
Def
Min
Max
Acc
13.3.7
3674 Compare delay
s
FLOAT
0.0
0.0
30.0
ERW
Setting of the delay for signalling the result of the comparison.
Menu
PAR
Description
UM
Type
FB BIT
Def
Min
Max
Acc
13.3.8
3676 Compare output
BIT
16
0
0
1
ER
The status of the comparator output is displayed:
0
The result of the set comparison is negative
1
The result of the set comparison is positive
Summary of Contents for AFE200 4 Series
Page 94: ...94 AFE200 Instruction Manual 7 DIGITAL INPUTS ...
Page 97: ... AFE200 Instruction Manual 97 8 DIGITAL OUTPUTS ...
Page 203: ... AFE200 Instruction Manual 203 Commands ...
Page 204: ...204 AFE200 Instruction Manual Digital inputs ...
Page 205: ... AFE200 Instruction Manual 205 Digital outputs ...
Page 206: ...206 AFE200 Instruction Manual Analog inputs ...
Page 207: ... AFE200 Instruction Manual 207 ...
Page 208: ...208 AFE200 Instruction Manual Analog outputs ...
Page 209: ... AFE200 Instruction Manual 209 Current Control ...
Page 210: ...210 AFE200 Instruction Manual Active Curr Config ...
Page 211: ... AFE200 Instruction Manual 211 Functions ...
Page 212: ......
Page 213: ......