ADV200 • Quick start up guide - Specification and installation
67
Step 7 - Speed tests
In this step the basic settings in order to perform a functional test of the drive-
motor system are described. This functional test uses
factory settings as far
as the analog and digital commands of the drive are concerned
. The preset
regulation mode is V/f.
• Basic connections for the speed test
S1+
1
S1-
C1
C2
C3
+1
0
V
0
V1
0
Analog input 1
COM-DI
0
V 24V
- 1
0
V
S3
9
7
8
FR reverse src
Enable
FR forward src
+24V OUT
Dig.inp 1
Dig.inp 2
Dig.inp E
2
+
-
R1
(2 ...
5
kohm)
After making the connections described in the previous section, proceed as fol-
lows to start the motor rotating:
1. Make sure the analog signal or potentiometer are set to the minimum value.
2. Close
the
Enable
contact (terminals S3 – 7)
3. Close
the
FR forward src (PAR 1042)
contact, terminals S3 – 8. The drive
starts magnetizing the motor
4. Increase the reference signal gradually using the potentiometer or analog
signal
5. If the motor rotates anti-clockwise with the
FR forward src (PAR 1042)
com-
mand and a positive analog reference, stop the drive, disconnect the power
supply and invert two phases between U, V and W.
6. Press
the
DISP
key to check that the voltage, current and output frequency
values are correct in relation to the type of motor and the set speed reference
value.
7. If all the parameters are correct, increase the analog reference to the full scale
value and check that the output voltage is the same as that on the motor data
plate, that the current is approximately equal to the magnetizing current (for
a standard asynchronous motor this is usually between 25% and 40% of the
rated current) and that the output frequency is 50 Hz.
8. If the motor does not reach its maximum speed, self-tuning of the analog input
may be necessary‘: set the input signal to its maximum value and set the
An
inp 1 gain tune
parameter (PAR: 1508) to 1.
9. If the motor still rotates with a reference of zero, eliminate the condition by
self-tuning the analog input offset: set the input signal to its minimum value
and set 1 for
An inp 1 offset tune
(PAR: 1506).
10. To reverse the direction of rotation, keep closed the
FR forward src (PAR