Air conditioner--Refrigerant
z
The pressure of high and low
pressure end is low.
z
The pipeline from condenser
to expansion valve frosts.
z
Refrigerant flow in adjuster
is obstructed by impurity.
z
Change the condenser.
z
Adjuster is obstructed.
Phenomenon
Possible reason
Diagnose
Method
State: cooling degree is not enough
(4) Refrigerant cycle is poor
(5) Refrigerant does not have any cycle.
z
Low pressure side is
vacuum, and pressure at
high pressure side is low.
z
The pipeline of front and
rear end of expansion
valve or adjuster frosts or
dews.
z
Refrigerant flow in cool-
ing system is obstructed
by water vapor or dust.
z
Refrigerant flow is ob-
structed by expansion
valve.
(1)Check the expansion
valve.
(2)Remove the dirt in ex-
pansion valve with high
pressure air.
(3)Change condenser.
(4)Take out vacuum and fill
applicable refrigerant.
(5)If this is caused by ex-
pansion valve leakage,
change the valve.
Refrigerant does not flow.
Phenomenon
Possible reason
Diagnose
Method
State: not cool (sometime cool)
217
Summary of Contents for FC
Page 1: ......
Page 2: ......
Page 302: ...Light Side turning light Side turning light Components Side turning light 291 ...
Page 409: ...Electric glass lifter Electrical schematic diagram Electric glass lifter 398 ...
Page 412: ...Electric rearview mirror Electrical schematic diagram Electric rearview mirror 401 ...
Page 413: ...Reversing radar system Electrical schematic diagram Reversing radar system 402 ...
Page 414: ...Safety airbag system Electrical schematic diagram Safety airbag system 403 ...
Page 418: ...Combination instrument Electrical schematic diagram Combination instrument 407 ...