(1) Refrigerant system with normal function.
Meter reading
Low pressure end:
0.15-0.25Mpa
High pressure end:
1.37-1.57Mpa
(2) Water in cooling system.
Air conditioner--Refrigerant
W h e n c o o l i n g s y s t e m i s
working, the pressure in low
pressure end changes to
vacuum or normal periodically.
Water vapor enters refrigerant
system, and freezes on the ex-
pansion valve, the system
stops cycle in short time, when
ice melts, it returns to normal
again.
(1)Change the condenser.
(2)Remove water in pipeline
with method of taking out
vacuum repeatedly.
( 3 ) F i l l a p p l i c a b l e n e w
refrigerant.
z
Dryer locates at full humidity
state.
z
Water vapor of refrigerant
freezes on the outlet orifice
of expansion valve to ob-
stacle freezing cycle.
Phenomenon
Possible reason
Diagnose
Method
(3) Lack refrigerant
Situation: too cold periodically, then lose cooling degree.
z
The pressure of high and low
pressure end is low.
z
T h e r e i s a i r b u b b l e o n
window.
z
Refrigerant leaks.
Some part of refrigerant system
leaks.
( 1 ) C h e c k i t w i t h l e a k a g e
measurer, if necessary, re-
pair it.
(2)Fill refrigerant to applicable
quantity.
(3)If meter pressure reading is
0, after checking and repair-
ing leaking position, take out
vacuum.
z
Refrigerant in system lacks.
z
C o o l i n g d e g r e e i s n o t
enough.
Phenomenon
Possible reason
Diagnose
Method
State: lack refrigerant
216
Summary of Contents for FC
Page 1: ......
Page 2: ......
Page 302: ...Light Side turning light Side turning light Components Side turning light 291 ...
Page 409: ...Electric glass lifter Electrical schematic diagram Electric glass lifter 398 ...
Page 412: ...Electric rearview mirror Electrical schematic diagram Electric rearview mirror 401 ...
Page 413: ...Reversing radar system Electrical schematic diagram Reversing radar system 402 ...
Page 414: ...Safety airbag system Electrical schematic diagram Safety airbag system 403 ...
Page 418: ...Combination instrument Electrical schematic diagram Combination instrument 407 ...