List of tools
Tool
Material no.
Flat-nose pliers
---
Pin punch/mandrel Ø6.0 mm
---
10.5
Removing the Control Top from the Valve
Fig.15
Requirement:
•
Make sure that the solenoid valve is not actuated.
Hint!
The pneumatic and electrical connections can remain on the control
top.
Carry out the following steps:
1.
Release the screw connection (39) and remove the clamp ring (15).
2.
Pull the control top vertically off the valve.
®
The green light goes off and is replaced with a yellow flashing light.
®
Done
Hint!
When the colours are swapped, the feedback signals are also
swapped!
10.6
Dismantling the Control Top into its Components
10.6.1 Variants of the Control Top
The control top can be fitted with:
•
1 NC solenoid valve or
•
without solenoid valve with 1 valve plate.
10.6.2 Removing the Cap
Maintenance
Removing the Control Top from the Valve
430BAL014475EN_2
03.09.2021
43
Summary of Contents for T.VIS M-20 FDD