In general, only original spare parts supplied by GEA Tuchenhagen GmbH
should be fitted. This ensures that the component is always operating properly
and efficiently.
2.4
IP Protection classes
The control top T.VIS M-20 FDD in its standard version fulfils the requirements of
protection class IP66, IP 67 and IP69 (DIN EN 60529) and protection class
IP6k9k (ISO 20653).
IP classes provide information about the degree of protection an electrical device
housing provides against the ingress of solids (first digit) or humidity (second
digit). So-called IP codes are assigned to the protected systems. Its digits
represent common possible errors the system is protected from. The code always
starts with the letter IP for “international protection”.
First digit *
Meaning
ISO 20653
DIN EN 60529
Protection against contact
Protection against solids
6k
6
Complete contact protection
Complete protection against dust
ingression (dustproof)
Second digit *
Meaning
ISO 20653
DIN EN 60529
Protection against humidity
5
5
Protected against water jet (nozzle) from any angle
6
6
Protected against powerful water jets
6k
Protected against powerful water jets under increased pressure
7
7
Protected against temporary immersion
9
Protected against high pressure spray downs
9k
Protected against high pressure spray downs
* For additional digits and more detailed descriptions please refer to the pertinent standard.
Digits not to be mentioned can be replaced by the letter x (e. g. IPx6).
Concerning the ingress of humidity, IPx6 includes all lower IP classes. This is,
however, not the case for the higher protection class IPx7!
Hint!
The specified IP classes only apply if the connectors are connected
correctly, if the cable gland is properly sealed and if the control top is
fitted on the valve, see Chapter 6, Page 28.
2.5
General safety instructions and dangers
The component is safe to operate. It was built according to state-of-the-art
science and technology.
Nevertheless, dangers can arise from the component, if:
•
the component is not used as intended
•
the component is used improperly
•
the component is operated under impermissible conditions
Safety
IP Protection classes
430BAL014475EN_2
03.09.2021
11
Summary of Contents for T.VIS M-20 FDD
Page 57: ...Appendix 430BAL014475EN_2 03 09 2021 57...