Technical data: electrical specifications
Designation
Description
Protection class ISO 20653
IP69k - high pressure
Fitting position
Restriction through ventilation E2:
Never direct ventilation (E2) vertically upwards
EC EMC directives
2014/30/EU
Immunity for industrial environments
Radio frequency interference
EN 61000-6-2: 2005
EN ISO 61000-6-4:2007 + A1: 2011
EC Low Voltage Directive
73/23/EEC
Electrical wiring configuration
–
Terminal strip
Hint!
Switching point tolerances, see Section 5.4, Page 26
5.3
Specification sensor module 24V DC Version
Type designation: 221-589,108
Technical data: supply
Designation
Description
Supply voltage UV
24 V DC (+20 % … -25 %)
Current consumption
–
No-load current
≤ 30 mA
–
per solenoid valve NC
35...45 mA
–
max. load of the feedback 50 mA
50 mA
Total
approx. 125 mA
Technical data: outputs
Designation
Description
Output voltage
High = UV - ≤ 1 V Low = ≤ 5 V
Max. current per output
100 mA short circuit proof
Switching frequency (ohmic + inductive loads ≤
25 mH)
2 Hz
Technical data
Specification sensor module 24V DC Version
430BAL014475EN_2
03.09.2021
25