Fig.17
Requirement:
•
Only use solenoid valves specified in chapter “Technical data”.
Hint!
In order to avoid or minimize the possibility of damage from
electrostatic discharge:
- Observe the requirements of DIN EN 61340-2-1 and 5-2.
- Be careful not to touch the electronic components!
Caution!
Risk of burns from the solenoid valve as a result of long switch-
on time and high ambient temperature
Risk of burns from the solenoid valve
► Allow to cool before dismantling.
Carry out the following steps:
1.
Undo the connector of the solenoid valve at the sensor module (43)
2.
Undo the screws (66) and separate the solenoid valve (63) from the
pneumatic block (8).
3.
Undo the screws (65.1) or, if present, separate the valve plate (65) from the
pneumatic block (8).
®
Done
Hint!
Fit the solenoid valve or valve plate in reverse order.
Lightly grease the seals before fitting them to prevent them from
falling out!
Maintenance
Dismantling the Control Top into its Components
430BAL014475EN_2
03.09.2021
45