6.6.1
Mounting to VARIVENT Valve or STERICOM Valve Types N_A/D, R
Fig.30
Notice
The permanent magnet on the switch bar is fragile.
Damage to the permanent magnet.
► Protect the permanent magnet against impact stress.
Notice
Magnetic fields resulting from the permanent magnet on the
switch bar.
Magnetic fields can delete data carriers and affect or destroy electronic or
mechanical components.
► Protect the components against the magnetic fields from the switch bar.
Requirement:
•
Pay attention not to kink the air hoses when mounting the control top.
Carry out the following steps:
1.
Check that the switch bar (1) is firmly in place. If necessary, tighten at (1.2)
using an a/f 13 jaw wrench, 2 Nm.
2.
Fit the control top (B) over the switch bar (1) and on the actuator (A.1).
3.
Tighten the clamp connection (15) and screws (39) to a torque of 1 Nm.
4.
Align the pneumatic and electrical connections in accordance with the valve
block configuration.
5.
Carry out commissioning, see chapter “Commissioning“.
®
Done.