an additional adapter module for the interface modules AS-Interface,
DeviceNet (optional),
•
a maximum of three solenoid valves for the actuation of the main stroke and
the lift strokes,
•
a logic element NOT (optional) for backup of the valve's main spring or for the
actuation of indifferent actuators (air/air),
•
a connection for an external proximity switch for monitoring the non-actuated
position of the double-disk (optional),
•
an exhaust air throttle (optional) for the infinitely adjustable setting of the
closing velocity of the main stroke,
•
a supply air throttle (optional) for the infinitely adjustable setting of the
opening velocity of the main stroke.
The permanent magnet on the switch bar (1) is fragile and must therefore be
protected against mechanical impact.
Magnetic fields can delete data carriers and affect or destroy electronic or
mechanical components. Avoid any influence of external magnetic fields on the
sensor system!
Do not perform welding work in the vicinity of the control top, as this could cause
data losses.
Description
Design
430BAL010697EN_2