5
Technical data
5.1
Type plate
The type plate is used to uniquely identify the control top.
Fig.8:
Control top type plate(Optional: UL/CSA
marking)
Code/Type
TM15
P
2
B
A
M
Item in the order code
14
15
16
17
18
19
Explanation of the items in the order code
Item in the order code
Designation
Explanation
14
Feedback location
T M 1 5
Control Top T.VIS M-15
15
Control top type
N
without solenoid valve
P
1 solenoid valve Y1
M
1 solenoid valve Y1
(retrofittable: Y2, Y3)
N
2 solenoid valves Y1,
Y2/2
Y1=main stroke
Y2=lifting of the valve
disk
retrofittable: Y3)
J
2 solenoid valves Y1, Y3
Y1=main stroke
Y3=lifting of the double-
disk for the external air
connection of an air/air
actuator or an external
process valve
retrofittable: Y2)