3.
Tighten the proximity switch nut (2) with the countersunk screw (3).
Fig.59
®
Done.
Adjusting the proximity switch holder
Carry out the following steps:
1.
Screw the adjusting screw (6) into the proximity switch holder until it reaches
the upper edge of the balancer (7).
Fig.60
2.
By slightly slackening the countersunk screw, position the proximity switch
holder in the slot in the lantern so that the point of the adjusting screw (6)
rests on the shoulder of the upper balancer in the direction of the actuator (A).
3.
Fix the proximity switch holder in position with the countersunk screw (3).
Fig.61
®
Done.
Fitting the proximity switch
Carry out the following steps:
1.
Remove the adjusting screw (6).
Start-up
Adjusting the Proximity Switch in the lantern of PMO Valve Type M/2.0
430BAL010697EN_2
15.04.2020
85