background image

DIMENSIONS AND 

CLEARANCES

Provide adequate clearances between the 

range and adjacent combustible surfaces. 

These dimensions must be met for safe use of 

your range. 
Allow 30” (76.2 cm) minimum clearance 

between burners and bottom of unprotected 

wood or metal cabinet, or allow a 24” (61 cm) 

minimum when bottom of wood or metal cabinet 

is protected by no less than 1/4” (6.4 mm) thick 

flame-retardant millboard covered with no less 

than No. 28 MSG sheet metal (.015” [.38 mm] 

thick), .015” (.38 mm) thick stainless steel, .025” 

(0.64 mm) aluminum or .020” (0.5 mm) copper.
Installation of a listed microwave oven or 

cooking appliance over the cooktop shall 

conform to the installation instructions packed 

with that appliance.
For island installation, maintain 2-1/2” minimum 

from cutout to back edge of countertop and 

3” minimum from cutout to side edges of 

countertop.

DIMENSIONS AND CLEARANCES (CONT.)

GAS PIPE AND ELECTRICAL OUTLET LOCATIONS

CAUTION

 

To prevent 

drafts from affecting burner 

operation, seal all openings 

in floor under appliance and 

behind appliance wall.

1 1/8"

47 1/2"

29 1/2"

w/ handle

26 7/8"

w/o handle

30"

36 1/4" ± 1/4

18”

Minimum 

to cabinets 

above counter

0”

Minimum

to cabinets 

below 

cooktop

Recommended

30”

Minimum 

30”

16”

Max to 

cabinets 

above 

counter 

6” Right side

6” Left side

Minimum

to side wall

36”

30”

2”

3”

9”

7”

8”

7 1/2”

2 1/4”

24”

Wall-Mounted

Side Wall

Gas

supply

Electrical

 

supply

For all installations, install the required rear trim to back of range with 4 screws provided.

Screws

Rear Trim

Back of 

Range

Summary of Contents for P2S930

Page 1: ...ccordance with the National Electrical Code ANSI NFPA 70 latest edition In Canada electrical grounding must be in accordance with the current CSA C22 1 Canadian Electrical Code Part 1 and or local codes See Electrical Connections in this section Do not install this product with an air curtain hood or other range hood that operates by blowing air down on the cooktop This airflow may interfere with ...

Page 2: ...te to consumer Keep these instructions for future reference Servicer The electrical diagram is in an envelope attached to the back of the range Proper installation is the responsibility of the installer Product failure due to improper installation is not covered under warranty Before installing your range on linoleum or any other synthetic floor covering make sure the floor covering can withstand ...

Page 3: ...installation instructions packed with that appliance For island installation maintain 2 1 2 minimum from cutout to back edge of countertop and 3 minimum from cutout to side edges of countertop DIMENSIONS AND CLEARANCES CONT GAS PIPE AND ELECTRICAL OUTLET LOCATIONS CAUTION To prevent drafts from affecting burner operation seal all openings in floor under appliance and behind appliance wall 1 1 8 47...

Page 4: ...O PROPANE GAS OR CONVERTING BACK TO NATURAL GAS FROM PROPANE This range leaves the factory set for use with natural gas If you want to convert to propane gas the conversion must be performed by a qualified propane gas installer The conversion orifices and instructions can be found on back of the range Keep these instructions and all orifices in case you want to convert back to natural gas Rear of ...

Page 5: ...or shock do not use an extension cord with this appliance WARNING To prevent shock remove house fuse or open circuit breaker before beginning installation We recommend you have the electrical wiring and hookup of your range connected by a qualified electrician After installation have the electrician show you how to disconnect power from the range You must use a single phase 120 208 VAC or 120 240 ...

Page 6: ...k Do not loosen the upper screws B Remove the ground screw and ground plate and retain them C Cut the ground strap below the terminal block and discard the lower section D Insert the ground screw through the ground plate removed earlier and back into the range frame Tighten securely but do not over tighten 15 to 20 in lbs E Insert the 3 terminal screws through each power cord terminal ring and bac...

Page 7: ...adapter to the NPT internal thread of the manual shut off valve taking care to back up the shut off valve to keep it from turning D Connect flexible metal appliance connector to the adapter on the range Position range to permit connection at the shut off valve E When all connections have been made make sure all range controls are in the off position and turn on the main gas supply valve Use a liqu...

Page 8: ...ully engaged with the anti tip device If not remove the unit and adjust the height of the rear leg so that it is properly engaged Spirit level X Y NOTE Cooktop must be at or above counter Cooktop 0 or Greater Counter 10 FINAL INSTALLATION CHECKLIST Check to make sure the circuit breaker is closed RESET or the circuit fuses are replaced Be sure power is in service to the building Check that all pac...

Page 9: ...ectricidad National Electric Code ANSI NFPA NO 70 última edición En Canadá la conexión a tierra se deberá realizar de acuerdo con la Parte 1 del Código de Electricidad de Canadá CSA C22 1 y o los códigos locales En esta sección consulte las Conexiones Eléctricas No instale este producto con una campana con cortina de aire u otra campana de cocina que funcione llevando aire a la placa de cocción El...

Page 10: ...para referencia futura Servicio Técnico El diagrama eléctrico se encuentra en un sobre adjunto al reverso de la cocina La correcta instalación del producto es responsabilidad del instalador Si se producen fallas en el producto debido a una instalación inadecuada la Garantía no cubrirá las mismas Antes de instalar su cocina sobre linóleo y cualquier otro revestimiento de piso sintético asegúrese de...

Page 11: ...a isla deje un espacio mínimo de 2 desde la abertura hasta el extremo trasero de la mesada y un mínimo de 3 desde la abertura hasta los extremos laterales de la mesada 1 1 8 47 1 2 29 1 2 w handle 26 7 8 w o handle 30 36 1 4 1 4 Sin manija Con manija Para todas las instalaciones instale el borde trasero requerido en la parte trasera de la cocina con los 4 tornillos provistos Tornillos Borde Traser...

Page 12: ...nstrucciones se podrán encontrar en la parte trasera de la cocina Guarde estas instrucciones y todo orificios en caso de que lo desee convertir nuevamente a gas natural Parte Trasera de la Estufa Kit del Orificio la ubicación puede variar Tapa del Bloque Terminal Tornillos para retirar la tapa del bloque terminal NSTALACIÓN EN ALTITUDES ELEVADAS A más de 6000 pies el producto configurado para gas ...

Page 13: ...VERTENCIA Para prevenir una descarga eléctrica quite el fusible o abra el interruptor de circuitos antes de comenzar la instalación Recomendamos que un electricista calificado conecte el cableado eléctrico y su cocina Después de la instalación solicite al electricista que le indique cómo desconectar la energía de la cocina Usted debe usar un sistema eléctrico de 60 hercios CA de fase única de 120 ...

Page 14: ...n a tierra que está debajo del bloque terminal y descarte la sección inferior D Inserte el tornillo de conexión a tierra a través de la placa de conexión a tierra retirada anteriormente y nuevamente en la estructura de la cocina Ajuste de forma segura pero sin ajustar en exceso entre 15 y 20 pulgadas libra E Inserte los 3 tornillos de la terminal a través de cada anillo terminal del cable de corri...

Page 15: ... interna de NPT de la válvula de cierre manual procurando evitar que la válvula de cierre no gire D Conecte el conector de metal flexible del electrodoméstico al adaptador de la cocina Posicione la cocina para permitir la conexión en la válvula de cierre E Cuando todas las conexiones se hayan realizado asegúrese de que todos los controles de la cocina estén en la posición de apagado y encienda la ...

Page 16: ...tivolcaduras De no ser así retire la unidad y ajuste la altura de la pata trasera de modo que quede correctamente adherida Nivel de Agua X Y NOTA La placa de cocción debe estar a la misma altura o más arriba que la mesada Mesada 0 o Superior Placa de Cocción 10 LISTA DE CONTROL FINAL DE LA INSTALACIÓN Verifique que el interruptor de circuitos se encuentre cerrado RESET o que los fusibles del circu...