background image

2

  POWER CORD AND CONDUIT INSTALLATION

A

   Remove wire cover (on the back of range) by removing screws using a 1/4” nut driver. You 

can access the terminal block by either removing a terminal block cover (on some models) or 

the wire cover. Do not discard these screws.

B

   For power cord and 1” conduit only, remove 

the knockout ring (1

3

8

”) located on bracket 

directly below the terminal block. To remove 

the knockout, use a pair of pliers to bend the 

knockout ring away from the bracket and 

twist until ring is removed.

D

   For 3/4” conduit installations only, purchase a squeeze connector matching the diameter  

of your conduit and assemble it in the hole. Insert the conduit through the squeeze connector  

and tighten. Allow enough slack to easily attach the wires to the terminal block. 

NOTE:

 Do 

not install the conduit without a squeeze connector. The squeeze connector MUST be 

installed before reinstalling the rear terminal block.

Knockout 

ring in 

bracket

Knockout ring 

removed

Terminal block 

(appearance  

may vary)

C

   For power cord installations only (see 

the next step if using conduit), assemble 

the strain relief in the hole. Insert the 

power cord through the strain relief and 

tighten. Allow enough slack to easily 

attach the cord terminals to the terminal 

block. If tabs are present at the end of 

the winged strain relief, they can be 

removed for better fit.

 

 

NOTE:

 Do not install the power cord 

without a strain relief. The strain relief 

bracket MUST be installed before 

reinstalling the rear range wiring cover.

Power cord

Strain relief

Terminal 

block

Bracket

Squeeze 

connector

Terminal block

Conduit

Bracket

Proceed to step 5 or 6.

Rear of Range

Orifice Kit 

(location may vary)

Terminal 

Block Cover

Screws to 

remove terminal 

block cover

1

  ELECTRICAL REQUIREMENTS

WARNING

 This appliance must be properly grounded.

WARNING

 All new constructions, mobile homes, recreational vehicles and installations 

where local codes do not allow grounding through neutral, require a 4-conductor UL-listed range cord.

WARNING

 To prevent fire or shock, do not use an extension cord with this appliance. 

WARNING

 To prevent shock, remove house fuse or open circuit breaker before 

beginning installation.
We recommend you have the electrical wiring and hookup of your range connected by a qualified 

electrician. After installation, have the electrician show you how to disconnect power from the range.
You must use a single-phase, 120/208 VAC or 120/240 VAC, 60 hertz electrical system. If you 

connect to aluminum wiring, properly installed connectors approved for use with aluminum wiring 

must be used.
Effective January 1, 1996, the National Electrical Code requires that new construction (not existing) 

utilize a 4-conductor connection to an electric range. When installing an electric range in new 

construction, mobile home, recreational vehicle, or an area where local codes prohibit grounding 

through the neutral conductor, refer to the section on four-conductor branch circuit connections.
Check with your local utilities for electrical codes which apply in your area. Failure to wire your oven 

according to governing codes could result in a hazardous condition. If there are no local codes, 

your oven must be wired and fused to meet the National Electrical Code, NFPA No. 70 – latest 

edition, available from the National Fire Protection Association.
This appliance must be supplied with the proper voltage and frequency, and connected to an 

individual, properly grounded, 30 amp (minimum) branch circuit protected by a circuit breaker or 

time-delay fuse.
Use only a 3-conductor or a 4-conductor UL-listed range cord. These cords may be provided with 

ring terminals on wire and a strain relief device.
A range cord rated at 30 amps with 125/250 minimum volt range is required. A 50 amp range cord 

is not recommended but if used, it should be marked for use with nominal 1

3

8

” diameter connection 

openings. Care should be taken to center the cable and strain relief within the knockout hole to 

keep the edge from damaging the cable.
The rating plate is located on the oven frame or on the side of the drawer frame.

NOTE:

 Use of automatic, wireless or wired external switches that shut off power to the appliances, 

are not recommended for this product.

Rating plate

SINGLE OVEN

Summary of Contents for P2S930

Page 1: ...ccordance with the National Electrical Code ANSI NFPA 70 latest edition In Canada electrical grounding must be in accordance with the current CSA C22 1 Canadian Electrical Code Part 1 and or local codes See Electrical Connections in this section Do not install this product with an air curtain hood or other range hood that operates by blowing air down on the cooktop This airflow may interfere with ...

Page 2: ...te to consumer Keep these instructions for future reference Servicer The electrical diagram is in an envelope attached to the back of the range Proper installation is the responsibility of the installer Product failure due to improper installation is not covered under warranty Before installing your range on linoleum or any other synthetic floor covering make sure the floor covering can withstand ...

Page 3: ...installation instructions packed with that appliance For island installation maintain 2 1 2 minimum from cutout to back edge of countertop and 3 minimum from cutout to side edges of countertop DIMENSIONS AND CLEARANCES CONT GAS PIPE AND ELECTRICAL OUTLET LOCATIONS CAUTION To prevent drafts from affecting burner operation seal all openings in floor under appliance and behind appliance wall 1 1 8 47...

Page 4: ...O PROPANE GAS OR CONVERTING BACK TO NATURAL GAS FROM PROPANE This range leaves the factory set for use with natural gas If you want to convert to propane gas the conversion must be performed by a qualified propane gas installer The conversion orifices and instructions can be found on back of the range Keep these instructions and all orifices in case you want to convert back to natural gas Rear of ...

Page 5: ...or shock do not use an extension cord with this appliance WARNING To prevent shock remove house fuse or open circuit breaker before beginning installation We recommend you have the electrical wiring and hookup of your range connected by a qualified electrician After installation have the electrician show you how to disconnect power from the range You must use a single phase 120 208 VAC or 120 240 ...

Page 6: ...k Do not loosen the upper screws B Remove the ground screw and ground plate and retain them C Cut the ground strap below the terminal block and discard the lower section D Insert the ground screw through the ground plate removed earlier and back into the range frame Tighten securely but do not over tighten 15 to 20 in lbs E Insert the 3 terminal screws through each power cord terminal ring and bac...

Page 7: ...adapter to the NPT internal thread of the manual shut off valve taking care to back up the shut off valve to keep it from turning D Connect flexible metal appliance connector to the adapter on the range Position range to permit connection at the shut off valve E When all connections have been made make sure all range controls are in the off position and turn on the main gas supply valve Use a liqu...

Page 8: ...ully engaged with the anti tip device If not remove the unit and adjust the height of the rear leg so that it is properly engaged Spirit level X Y NOTE Cooktop must be at or above counter Cooktop 0 or Greater Counter 10 FINAL INSTALLATION CHECKLIST Check to make sure the circuit breaker is closed RESET or the circuit fuses are replaced Be sure power is in service to the building Check that all pac...

Page 9: ...ectricidad National Electric Code ANSI NFPA NO 70 última edición En Canadá la conexión a tierra se deberá realizar de acuerdo con la Parte 1 del Código de Electricidad de Canadá CSA C22 1 y o los códigos locales En esta sección consulte las Conexiones Eléctricas No instale este producto con una campana con cortina de aire u otra campana de cocina que funcione llevando aire a la placa de cocción El...

Page 10: ...para referencia futura Servicio Técnico El diagrama eléctrico se encuentra en un sobre adjunto al reverso de la cocina La correcta instalación del producto es responsabilidad del instalador Si se producen fallas en el producto debido a una instalación inadecuada la Garantía no cubrirá las mismas Antes de instalar su cocina sobre linóleo y cualquier otro revestimiento de piso sintético asegúrese de...

Page 11: ...a isla deje un espacio mínimo de 2 desde la abertura hasta el extremo trasero de la mesada y un mínimo de 3 desde la abertura hasta los extremos laterales de la mesada 1 1 8 47 1 2 29 1 2 w handle 26 7 8 w o handle 30 36 1 4 1 4 Sin manija Con manija Para todas las instalaciones instale el borde trasero requerido en la parte trasera de la cocina con los 4 tornillos provistos Tornillos Borde Traser...

Page 12: ...nstrucciones se podrán encontrar en la parte trasera de la cocina Guarde estas instrucciones y todo orificios en caso de que lo desee convertir nuevamente a gas natural Parte Trasera de la Estufa Kit del Orificio la ubicación puede variar Tapa del Bloque Terminal Tornillos para retirar la tapa del bloque terminal NSTALACIÓN EN ALTITUDES ELEVADAS A más de 6000 pies el producto configurado para gas ...

Page 13: ...VERTENCIA Para prevenir una descarga eléctrica quite el fusible o abra el interruptor de circuitos antes de comenzar la instalación Recomendamos que un electricista calificado conecte el cableado eléctrico y su cocina Después de la instalación solicite al electricista que le indique cómo desconectar la energía de la cocina Usted debe usar un sistema eléctrico de 60 hercios CA de fase única de 120 ...

Page 14: ...n a tierra que está debajo del bloque terminal y descarte la sección inferior D Inserte el tornillo de conexión a tierra a través de la placa de conexión a tierra retirada anteriormente y nuevamente en la estructura de la cocina Ajuste de forma segura pero sin ajustar en exceso entre 15 y 20 pulgadas libra E Inserte los 3 tornillos de la terminal a través de cada anillo terminal del cable de corri...

Page 15: ... interna de NPT de la válvula de cierre manual procurando evitar que la válvula de cierre no gire D Conecte el conector de metal flexible del electrodoméstico al adaptador de la cocina Posicione la cocina para permitir la conexión en la válvula de cierre E Cuando todas las conexiones se hayan realizado asegúrese de que todos los controles de la cocina estén en la posición de apagado y encienda la ...

Page 16: ...tivolcaduras De no ser así retire la unidad y ajuste la altura de la pata trasera de modo que quede correctamente adherida Nivel de Agua X Y NOTA La placa de cocción debe estar a la misma altura o más arriba que la mesada Mesada 0 o Superior Placa de Cocción 10 LISTA DE CONTROL FINAL DE LA INSTALACIÓN Verifique que el interruptor de circuitos se encuentre cerrado RESET o que los fusibles del circu...