GE P2S930 Installation Instruction Download Page 2

TOOLS YOU WILL NEED

MATERIALS YOU MAY NEED

■  Gas line shut-off valve

■  Pipe joint sealant or UL-approved pipe thread 

tape with Teflon* that resists action of natural 

and propane gases

■  Flexible metal appliance connector (1/2” I.D.). 

A 5-foot length is recommended for ease of 

installation but other lengths are acceptable. 

Never use an old connector when installing a 

new range.

■  Flare union adapter for connection to gas 

supply line (3/4” or 1/2” NPT x 1/2” I.D.)

■  Flare union adapter for connection to pressure 

regulator on range (1/2” NPT x 1/2” I.D.)

■  Liquid leak detector or soapy water.

■  (UL Listed 40 AMP) 

4-Wire Cord 4’ long OR 

3-Wire Cord 4’ long

*Teflon: Registered trademark of DuPont

BEFORE YOU BEGIN

IMPORTANT —

 

Save these 

instructions for local inspector’s use.

IMPORTANT 

 Observe all governing 

codes and ordinances.

IMPORTANT 

 Remove all packing 

material and literature from oven before 

connecting gas and electrical supply to range.

 

IMPORTANT 

 To avoid damage 

to your cabinets, check with your builder 

or cabinet supplier to make sure that the 

materials used will not discolor, delaminate 

or sustain other damage. This oven has been 

designed in accordance with the requirements 

of UL and CSA International and complies 

with the maximum allowable wood cabinet 

temperatures of 194°F (90°C).

Note to Installer

 – Be sure to leave these 

instructions with consumer.

Note to consumer

 – Keep these instructions 

for future reference.

Servicer

 – The electrical diagram is in an 

envelope attached to the back of the range.
Proper installation is the responsibility of the 

installer. 
Product failure due to improper installation is 

not covered under warranty.
Before installing your range on linoleum or 

any other synthetic floor covering, make sure 

the floor covering can withstand 180°F without 

shrinking, warping or discoloring. Do not install 

the range over carpeting unless a sheet of 

1/4” thick plywood or similar insulator is placed 

between the range and carpeting.

Mobile Home - Additional Installation 

Requirements

The installation of this range must conform 

to the Manufactured Home Construction and 

Safety Standard, Title 24 CFR, Part 3280 

(formerly the Federal Standard for Mobile 

Home Construction and Saftey, Title 24, 

HUD Part 280). When such standard is not 

applicable, use the Standard for Manufactured 

Home Installations, ANSI A225.1/NFPA 501A 

or with local codes.
In Canada, the installation of this range must 

conform with the current standards CAN/CSA-

A240-latest edition, or with local codes.
When this range is installed in a mobile 

home, it must be secured to the floor during 

transit. Any method of securing the range 

is adequate as long as it conforms to the 

standards listed above.

Drill with 1/8” Bit

Tin Snips

Tape Measure

Safety Glasses

Pliers

1/4” Nut Driver

Flat-blade 

screwdriver

Pipe wrenches (2)

(one for backup)

Phillips 

screwdriver

Open-end or  

adjustable wrench

Pencil and ruler

Level

Drill, awl or nail

Summary of Contents for P2S930

Page 1: ...ccordance with the National Electrical Code ANSI NFPA 70 latest edition In Canada electrical grounding must be in accordance with the current CSA C22 1 Canadian Electrical Code Part 1 and or local codes See Electrical Connections in this section Do not install this product with an air curtain hood or other range hood that operates by blowing air down on the cooktop This airflow may interfere with ...

Page 2: ...te to consumer Keep these instructions for future reference Servicer The electrical diagram is in an envelope attached to the back of the range Proper installation is the responsibility of the installer Product failure due to improper installation is not covered under warranty Before installing your range on linoleum or any other synthetic floor covering make sure the floor covering can withstand ...

Page 3: ...installation instructions packed with that appliance For island installation maintain 2 1 2 minimum from cutout to back edge of countertop and 3 minimum from cutout to side edges of countertop DIMENSIONS AND CLEARANCES CONT GAS PIPE AND ELECTRICAL OUTLET LOCATIONS CAUTION To prevent drafts from affecting burner operation seal all openings in floor under appliance and behind appliance wall 1 1 8 47...

Page 4: ...O PROPANE GAS OR CONVERTING BACK TO NATURAL GAS FROM PROPANE This range leaves the factory set for use with natural gas If you want to convert to propane gas the conversion must be performed by a qualified propane gas installer The conversion orifices and instructions can be found on back of the range Keep these instructions and all orifices in case you want to convert back to natural gas Rear of ...

Page 5: ...or shock do not use an extension cord with this appliance WARNING To prevent shock remove house fuse or open circuit breaker before beginning installation We recommend you have the electrical wiring and hookup of your range connected by a qualified electrician After installation have the electrician show you how to disconnect power from the range You must use a single phase 120 208 VAC or 120 240 ...

Page 6: ...k Do not loosen the upper screws B Remove the ground screw and ground plate and retain them C Cut the ground strap below the terminal block and discard the lower section D Insert the ground screw through the ground plate removed earlier and back into the range frame Tighten securely but do not over tighten 15 to 20 in lbs E Insert the 3 terminal screws through each power cord terminal ring and bac...

Page 7: ...adapter to the NPT internal thread of the manual shut off valve taking care to back up the shut off valve to keep it from turning D Connect flexible metal appliance connector to the adapter on the range Position range to permit connection at the shut off valve E When all connections have been made make sure all range controls are in the off position and turn on the main gas supply valve Use a liqu...

Page 8: ...ully engaged with the anti tip device If not remove the unit and adjust the height of the rear leg so that it is properly engaged Spirit level X Y NOTE Cooktop must be at or above counter Cooktop 0 or Greater Counter 10 FINAL INSTALLATION CHECKLIST Check to make sure the circuit breaker is closed RESET or the circuit fuses are replaced Be sure power is in service to the building Check that all pac...

Page 9: ...ectricidad National Electric Code ANSI NFPA NO 70 última edición En Canadá la conexión a tierra se deberá realizar de acuerdo con la Parte 1 del Código de Electricidad de Canadá CSA C22 1 y o los códigos locales En esta sección consulte las Conexiones Eléctricas No instale este producto con una campana con cortina de aire u otra campana de cocina que funcione llevando aire a la placa de cocción El...

Page 10: ...para referencia futura Servicio Técnico El diagrama eléctrico se encuentra en un sobre adjunto al reverso de la cocina La correcta instalación del producto es responsabilidad del instalador Si se producen fallas en el producto debido a una instalación inadecuada la Garantía no cubrirá las mismas Antes de instalar su cocina sobre linóleo y cualquier otro revestimiento de piso sintético asegúrese de...

Page 11: ...a isla deje un espacio mínimo de 2 desde la abertura hasta el extremo trasero de la mesada y un mínimo de 3 desde la abertura hasta los extremos laterales de la mesada 1 1 8 47 1 2 29 1 2 w handle 26 7 8 w o handle 30 36 1 4 1 4 Sin manija Con manija Para todas las instalaciones instale el borde trasero requerido en la parte trasera de la cocina con los 4 tornillos provistos Tornillos Borde Traser...

Page 12: ...nstrucciones se podrán encontrar en la parte trasera de la cocina Guarde estas instrucciones y todo orificios en caso de que lo desee convertir nuevamente a gas natural Parte Trasera de la Estufa Kit del Orificio la ubicación puede variar Tapa del Bloque Terminal Tornillos para retirar la tapa del bloque terminal NSTALACIÓN EN ALTITUDES ELEVADAS A más de 6000 pies el producto configurado para gas ...

Page 13: ...VERTENCIA Para prevenir una descarga eléctrica quite el fusible o abra el interruptor de circuitos antes de comenzar la instalación Recomendamos que un electricista calificado conecte el cableado eléctrico y su cocina Después de la instalación solicite al electricista que le indique cómo desconectar la energía de la cocina Usted debe usar un sistema eléctrico de 60 hercios CA de fase única de 120 ...

Page 14: ...n a tierra que está debajo del bloque terminal y descarte la sección inferior D Inserte el tornillo de conexión a tierra a través de la placa de conexión a tierra retirada anteriormente y nuevamente en la estructura de la cocina Ajuste de forma segura pero sin ajustar en exceso entre 15 y 20 pulgadas libra E Inserte los 3 tornillos de la terminal a través de cada anillo terminal del cable de corri...

Page 15: ... interna de NPT de la válvula de cierre manual procurando evitar que la válvula de cierre no gire D Conecte el conector de metal flexible del electrodoméstico al adaptador de la cocina Posicione la cocina para permitir la conexión en la válvula de cierre E Cuando todas las conexiones se hayan realizado asegúrese de que todos los controles de la cocina estén en la posición de apagado y encienda la ...

Page 16: ...tivolcaduras De no ser así retire la unidad y ajuste la altura de la pata trasera de modo que quede correctamente adherida Nivel de Agua X Y NOTA La placa de cocción debe estar a la misma altura o más arriba que la mesada Mesada 0 o Superior Placa de Cocción 10 LISTA DE CONTROL FINAL DE LA INSTALACIÓN Verifique que el interruptor de circuitos se encuentre cerrado RESET o que los fusibles del circu...

Reviews: