C–24
MULTINET4 MULTI-PORT SERIAL SERVER & MANAGED SWITCH – INSTRUCTION MANUAL
MODBUS MEMORY MAP
CHAPTER C: MODBUS MEMORY MAP
0438
2
Port18 - Number of frames with CRC error 0
429496
7295
1
-
F9
0
043A
2
Port18 - Number of oversized frames received 0
429496
7295
1
-
F9
0
043C
2
Port18 - Number of bad fragments rcvd(<64
bytes)
0
429496
7295
1
-
F9
0
043E
2
Port18 - Number of jabber frames received 0
429496
7295
1
-
F9
0
0440
2
Port18 - Number of collisions occured
0
429496
7295
1
-
F9
0
0442
2
Port18 - Number of late collisions occured
0
429496
7295
1
-
F9
0
0444
2
Port18 - Number of 64-byte frames rcvd/sent 0
429496
7295
1
-
F9
0
0446
2
Port18 - Number of 65-127 byte frames rcvd/
sent
0
429496
7295
1
-
F9
0
0448
2
Port18 - Number of 128-255 byte frames rcvd/
sent
0
429496
7295
1
-
F9
0
044A
2
Port18 - Number of 256-511 byte frames rcvd/
sent
0
429496
7295
1
-
F9
0
044C
2
Port18 - Number of 512-1023 byte frames rcvd/
sent
0
429496
7295
1
-
F9
0
044E
2
Port18 - Number of 1023-MAX byte frames
rcvd/sent
0
429496
7295
1
-
F9
0
0450
2
Port18 - Number of Mac Error Packets
0
429496
7295
1
-
F9
0
0452
2
Port18 - Number of dropped received packets 0
429496
7295
1
-
F9
0
0454
2
Port18 - Number of multicast frames sent 0
429496
7295
1
-
F9
0
0456
2
Port18 - Number of broadcast frames sent 0
429496
7295
1
-
F9
0
0458
2
Port18 - Number of <64 byte fragments w/ good
CRC
0
429496
7295
1
-
F9
0
045A
2
Port19 - Number of bytes received
0
429496
7295
1
-
F9
0
045C
2
Port19 - Number of bytes sent
0
429496
7295
1
-
F9
0
045E
2
Port19 - Number of frames received
0
429496
7295
1
-
F9
0
0460
2
Port19 - Number of frames sent
0
429496
7295
1
-
F9
0
0462
2
Port19 - Total bytes received
0
429496
7295
1
-
F9
0
0464
2
Port19 - Total frames received
0
429496
7295
1
-
F9
0
0466
2
Port19 - Number of broadcast frames received 0
429496
7295
1
-
F9
0
Address Qty
Description
Min
Max
Step Unit Format
Default