MULTINET4 MULTI-PORT SERIAL SERVER & MANAGED SWITCH – INSTRUCTION MANUAL
OVERVIEW
CHAPTER 1: OVERVIEW
1.2.4
Power Requirements
The power requirements of the Multinet4 are defined in the table below.
Dry Heat Temperature
EN/IEC 60068-2-2: 1994,1974
+85 deg startup for 16 hours
Humidity
NEMA TS2 2.1.5
-34 to 74C, 10-95%
MECHANICAL TESTS
Sinusoidal Vibration
EN/IEC 60255-21-1: 1996,1988 Class 1 - 10-150hz @2G
Shock and Bump
EN/IEC 60255-21-2: 1996,1988 Class 2 - 30G bump, 17G
shock
Shock
NEMA TS2 2.2.9
10G, x,,y,z axis
Vibration
MIL-STD -167-1
0.5G, 5-30 Hz
FUNCTIONAL TESTS
Operating Voltage
NEMA TS2 2.1.2
Max nominal rating
Operational frequency
NEMA TS2 2.1.3
N/- 3Hz
SAFETY TESTS
Dielectric IEEE
C37.90
2kV on Hi model & 500V on Lo
model
Dielectric IEC60255-5
2kV
H.V Impulse
IEEE C37.90
5kV
H.V Impulse
IEC60255-5
5kV
OTHERS
IP rating
IEC60529
IP20A
Standard Name
Standard Number:Date
code
Severity levels Tested
Table 1–3: Power Requirements
High Voltage AC/DC
Low Voltage DC
Voltage Input Range:
90-250 VAC/VDC
24-48 VDC
Max. Power (Watts):
27
27