5–22
MULTINET4 MULTI-PORT SERIAL SERVER & MANAGED SWITCH – INSTRUCTION MANUAL
THE CLI AND PROTOCOL MONITOR
CHAPTER 5: THE CLI AND PROTOCOL MONITOR
FIGURE 5–7: CLI: sw show command output - READY TO UPGRADE
5.
Perform the upgrade.
In the CLI command window enter the command sw upgrade. Confirm that you want to
carry out the upgrade by answering yes to the "are you sure" question.
6.
Reconnect to the CLI.
After the upgrade command has been issued your connection to the CLI will probably be
lost. Reconnect and run the sw show command.
FIGURE 5–8: CLI: sw show command output - UPGRADING
7.
Finalize.
Complete the upgrade procedure by entering the sw finalize command to approve the
new software image. Run the sw show command one last time to confirm the new
configuration.
FIGURE 5–9: CLI: sw show command output - UPGRADED
MN4
# sw show
Filename Version Use
dx800v140rc3.elf 1.4.0 Current
dx800v140rcQ.elf 1.4.0 New
Upgrade State: READY TO UPGRADE
MN4
# sw show
Filename Version Use
dx800v140rc3.elf 1.4.0 Fallback
dx800v140rcQ.elf 1.4.0 Current
Upgrade State: UPGRADING
MN4
# sw show
Filename Version Use
dx800v140rcQ.elf 1.4.0 Current
dx800v140rc3.elf 1.4.0 Fallback
Upgrade State: UPGRADED